EATON - MOELLER Z-R23/16-20 Z-R23/16-20 ICS-R16D024B200 EATON ELECTRIC Installation relay, 24 V DC, 2NO, 16A View larger
Images are for illustrative purposes only. Please refer to data sheet for details

Z-R23/16-20 ICS-R16D024B200 EATON ELECTRIC Installation relay, 24 V DC, 2NO, 16A

Z-R23/16-20

ICS-R16D024B200

ICS-R16D024B200

EATON - MOELLER

2 Pcs.

Installation relay, 24 V DC, 2NO, 16A Z-R23/16-20 Eaton Distribution parts. Installation relay, 24 V DC, 2NO, 16A Installation relay with manual operation, control voltage 24V DC, function: 2 NO, rated operational current 16 A, 240V AC, type conform to IEC/EN 60947-4-1, standard front dimension 45 mm, mounting width 1 MU, top-hat rail mounting.

Automation > Installation relay
Modular Switchgear – Others and Accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Distribution parts
Catalog Number
ICS-R16D024B200
Model Code
Z-R23/16-20
EAN
9010238030169
Product Length/Depth
90 mm
Product Height
73 mm
Product Width
17.5 mm
Product Weight
0.097 kg
Compliances
RoHS conform

Product specifications

Amperage Rating
16 A
Mounting method
DIN rail
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Equipment heat dissipation, current-dependent
0.8 W
Control voltage 1 type
DC
Control voltage 1 - max
26 V
Control voltage 1 - min
21 V
Control voltage 2 - max
0 V
Control voltage 2 - min
0 V
Frequency control voltage 1 - max
0 Hz
Frequency control voltage 1 - min
0 Hz
Frequency control voltage 2 - max
0 Hz
Frequency control voltage 2 - min
0 Hz
Incandescent lamp load - max
720 W
Load fluorescent lamp - max
303 VA
Load fluorescent lamp (duo circuit) - max
541 VA
Load fluorescent lamp (parallel compensated) - max
271 VA
Number of contacts (change-over contacts)
0
Number of contacts (normally closed contacts)
0
Number of contacts (normally open contacts)
2
Control voltage 2 type
AC/DC
Rated operational current for specified heat dissipation (In)
16 A
Supply voltage - max
240 V
Supply voltage - min
240 V
Switching current (cos phi = 0.6) - max
5 A
Width in number of modular spacings
1
Built-in depth
60 mm
Voltage type
AC
Functions
Mechanical

ETIM for ICS-R16D024B200 Modular devices for distribution board/surface mounting (EC001652)
Feature Name Feature Value
Function (EF000030) Mechanical
Mounting method (EF000003) DIN rail
Width in number of modular spacings (EF002950) 1
Built-in depth (EF000218) 60 mm
Number of contacts as normally open contact (EF008256) 2
Number of contacts as normally closed contact (EF008255) 0
Number of contacts as change-over contact (EF008257) 0
Control voltage 1 (EF002952) 21 V
Type of control voltage 1 (EF002954) DC
Frequency control voltage 1 (EF002956) 0 Hz
Control voltage 2 (EF002953) 0 V
Type of control voltage 2 (EF002955) AC/DC
Frequency control voltage 2 (EF002957) 0 Hz
Rated current (EF000227) 16 A
Supply voltage (EF004127) 240 V
Voltage type (supply voltage) (EF002991) AC
Max. incandescent lamp load (EF004952) 720 W
Max. load fluorescent lamp (EF004971) 303 VA
Max. load fluorescent lamp (Duo circuit) (EF004972) 541 VA
Max. load fluorescent lamp (parallel compensated) (EF004973) 271 VA
Max. switching current (cos phi = 0.6) (EF004920) 5 A

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.