View larger
XSDMV-240808-BF-2-PI 192615 Y7-192615 EATON ELECTRIC Miniature circuit breaker (MCB), 20A, 1p, C-Char, AC
XSDMV-240808-BF-2-PI
192615
Y7-192615
EATON - MOELLER
1 Pcs.
Automation > Door/operating panel (switchgear cabinet)
Enclosures
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This XSDMV-240808-BF-2-PI 192615 Y7-192615 EATON ELECTRIC Miniature circuit breaker (MCB), 20A, 1p, C-Char, AC serves as a compartment access door used to close off sub-distribution zones in modular electrical installations.
Exact pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated current: I n
- Rated switching capacity acc. to IEC/EN 60947-2: I cu
- Rated voltage according to IEC/EN 60947-2: U n
- Rated switching capacity acc. to IEC/EN 60947-2: I cu
- Rated voltage according to IEC/EN 60898-1: U n
- Rated switching capacity according to IEC/EN 60898-1: I cn
- Rated insulation voltage: U i
- Rated frequency: f
- Electrical: Operations
- Mechanical: Operations
- Model (EF000010): Compartment door
- Version as glazed door (EF006966): No
- Width (EF000008): 795 mm
- Height (EF000040): 197 mm
- Depth (EF000049): 82 mm
- EMC-version (EF001062): No
More info
▲Basic function | Miniature circuit-breakers | ||
Number of poles | 1 pole | ||
Tripping characteristic | C | ||
Application | Switchgear for industrial and advanced commercial applications | ||
Rated current | In | A | 20 |
Rated switching capacity acc. to IEC/EN 60947-2 | Icu | kA | 25 |
Product range | FAZ-T |
| Electrical | |||
Standards | IEC/EN 60947-2 | ||
Rated voltage according to IEC/EN 60947-2 | Un | V AC | 240 |
Rated switching capacity acc. to IEC/EN 60947-2 | Icu | kA | 25 |
Rated service short-circuit breaking capacity according to IEC/EN 60947-2 | Ics | 12,5 kA | |
Max operational voltage according to IEC/EN 60947-2 | V AC | 254 | |
Rated switching capacity according to IEC/EN 60947-2 (max operational voltage) | Icu | kA | 15 |
Rated service short-circuit breaking capacity according to IEC/EN 60947-2 (max operational voltage) | Ics | 7,5 kA | |
Max operational voltage DC according to IEC/EN 60947-2 | V DC | 60/pole | |
Rated voltage according to IEC/EN 60898-1 | Un | V AC | 240 |
Rated switching capacity according to IEC/EN 60898-1 | Icn | kA | 15 |
Rated service short-circuit breaking capacity according to IEC/EN 60898-1 | Ics | 7,5 kA | |
Rated insulation voltage | Ui | V | 440 |
Rated frequency | f | Hz | 50/60 |
Characteristic | B, C, D | ||
Direction of incoming supply | as required | ||
lifespan | |||
Electrical | Operations | ≧ 4000 | |
Mechanical | Operations | ≧ 10000 | |
| Mechanical | |||
Standard front dimension | mm | 45 | |
Enclosure height | mm | 80 | |
Mounting width per pole | mm | 17.5 | |
Mounting | Quick attachment with 3 latch positions for top-hat rail IEC/EN 60715 | ||
Degree of Protection | IP20 | ||
Terminals top and bottom | Twin-purpose terminals | ||
Terminal protection | Finger- and back-of-hand proof according to BGV A3 and ÖVE-EN 6 | ||
Terminal capacities | mm2 | 1 - 25 | |
Tightening torque of fixing screws | N/m | max. 2.4 | |
Thickness of busbar material | mm | 0.8 (exept N 0.5 SU) | |
Mounting position | As required | ||
| Circuit breakers and fuses (EG000020) / Miniature circuit breaker (MCB) (EC000042) | |||
| Electric engineering, automation, process control engineering / Electrical installation, device / Miniature circuit breaker system (MCB) / Miniature circuit breaker (MCB) ([email protected] [AAB905014]) | |||
Release characteristic | C | ||
Number of poles (total) | 1 | ||
Number of protected poles | 1 | ||
Rated current | A | 20 | |
Rated voltage | V | 240 | |
Rated insulation voltage Ui | V | 440 | |
Rated impulse withstand voltage Uimp | kV | 4 | |
Rated short-circuit breaking capacity Icn EN 60898 at 230 V | kA | 15 | |
Rated short-circuit breaking capacity Icn EN 60898 at 400 V | kA | 15 | |
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V | kA | 20 | |
Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V | kA | 20 | |
Voltage type | AC | ||
Frequency | Hz | 50 - 60 | |
Current limiting class | 3 | ||
Suitable for flush-mounted installation | No | ||
Concurrently switching N-neutral | No | ||
Over voltage category | 3 | ||
Pollution degree | 2 | ||
Additional equipment possible | Yes | ||
Width in number of modular spacings | 1 | ||
Built-in depth | mm | 70.5 | |
Degree of protection (IP) | IP20 | ||
Ambient temperature during operating | °C | -25 - 75 | |
Connectable conductor cross section multi-wired | mm² | 1 - 25 | |
Connectable conductor cross section solid-core | mm² | 1 - 25 | |