The XSDMV-240808-BF-2 Eaton Moeller miniature circuit breaker provides overcurrent and short-circuit protection for electrical branch circuits in industrial and commercial distribution systems. MCBs of this type automatically interrupt fault currents to prevent wiring damage and safeguard connected machinery from electrical overloads. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated current: I n
- Rated switching capacity acc. to IEC/EN 60947-2: I cu
- Rated voltage according to IEC/EN 60947-2: U n
- Rated switching capacity acc. to IEC/EN 60947-2: I cu
- Rated voltage according to IEC/EN 60898-1: U n
- Rated switching capacity according to IEC/EN 60898-1: I cn
- Rated insulation voltage: U i
- Rated frequency: f
- Electrical: Operations
- Mechanical: Operations
- Model (EF000010): Compartment door
- Version as glazed door (EF006966): No
- Width (EF000008): 795 mm
- Height (EF000040): 197 mm
- Depth (EF000049): 82 mm
- EMC-version (EF001062): No
More info
▲Basic function | Miniature circuit-breakers | ||
Number of poles | 1 pole | ||
Tripping characteristic | C | ||
Application | Switchgear for industrial and advanced commercial applications | ||
Rated current | In | A | 20 |
Rated switching capacity acc. to IEC/EN 60947-2 | Icu | kA | 25 |
Product range | FAZ-T |
| Electrical | |||
Standards | IEC/EN 60947-2 | ||
Rated voltage according to IEC/EN 60947-2 | Un | V AC | 240 |
Rated switching capacity acc. to IEC/EN 60947-2 | Icu | kA | 25 |
Rated service short-circuit breaking capacity according to IEC/EN 60947-2 | Ics | 12,5 kA | |
Max operational voltage according to IEC/EN 60947-2 | V AC | 254 | |
Rated switching capacity according to IEC/EN 60947-2 (max operational voltage) | Icu | kA | 15 |
Rated service short-circuit breaking capacity according to IEC/EN 60947-2 (max operational voltage) | Ics | 7,5 kA | |
Max operational voltage DC according to IEC/EN 60947-2 | V DC | 60/pole | |
Rated voltage according to IEC/EN 60898-1 | Un | V AC | 240 |
Rated switching capacity according to IEC/EN 60898-1 | Icn | kA | 15 |
Rated service short-circuit breaking capacity according to IEC/EN 60898-1 | Ics | 7,5 kA | |
Rated insulation voltage | Ui | V | 440 |
Rated frequency | f | Hz | 50/60 |
Characteristic | B, C, D | ||
Direction of incoming supply | as required | ||
lifespan | |||
Electrical | Operations | ≧ 4000 | |
Mechanical | Operations | ≧ 10000 | |
| Mechanical | |||
Standard front dimension | mm | 45 | |
Enclosure height | mm | 80 | |
Mounting width per pole | mm | 17.5 | |
Mounting | Quick attachment with 3 latch positions for top-hat rail IEC/EN 60715 | ||
Degree of Protection | IP20 | ||
Terminals top and bottom | Twin-purpose terminals | ||
Terminal protection | Finger- and back-of-hand proof according to BGV A3 and ÖVE-EN 6 | ||
Terminal capacities | mm2 | 1 - 25 | |
Tightening torque of fixing screws | N/m | max. 2.4 | |
Thickness of busbar material | mm | 0.8 (exept N 0.5 SU) | |
Mounting position | As required | ||
| Circuit breakers and fuses (EG000020) / Miniature circuit breaker (MCB) (EC000042) | |||
| Electric engineering, automation, process control engineering / Electrical installation, device / Miniature circuit breaker system (MCB) / Miniature circuit breaker (MCB) ([email protected] [AAB905014]) | |||
Release characteristic | C | ||
Number of poles (total) | 1 | ||
Number of protected poles | 1 | ||
Rated current | A | 20 | |
Rated voltage | V | 240 | |
Rated insulation voltage Ui | V | 440 | |
Rated impulse withstand voltage Uimp | kV | 4 | |
Rated short-circuit breaking capacity Icn EN 60898 at 230 V | kA | 15 | |
Rated short-circuit breaking capacity Icn EN 60898 at 400 V | kA | 15 | |
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V | kA | 20 | |
Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V | kA | 20 | |
Voltage type | AC | ||
Frequency | Hz | 50 - 60 | |
Current limiting class | 3 | ||
Suitable for flush-mounted installation | No | ||
Concurrently switching N-neutral | No | ||
Over voltage category | 3 | ||
Pollution degree | 2 | ||
Additional equipment possible | Yes | ||
Width in number of modular spacings | 1 | ||
Built-in depth | mm | 70.5 | |
Degree of protection (IP) | IP20 | ||
Ambient temperature during operating | °C | -25 - 75 | |
Connectable conductor cross section multi-wired | mm² | 1 - 25 | |
Connectable conductor cross section solid-core | mm² | 1 - 25 | |