Request QuoteProduct Overview
An XNH2-FCE-S400 EATON ELECTRIC NH fuse-switch is engineered for direct busbar installation, providing dependable three-pole circuit protection and load switching for commercial power distribution. Panel builders integrate these devices into modular distribution boards to manage high operating currents securely.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Version as main switch (EF006981): No
- Version as safety switch (EF006985): No
- Max. rated operation voltage Ue AC (EF007355): 500 V
- Rated permanent current Iu (EF001389): 400 A
- Rated operation power at AC-23, 400 V (EF007027): 0 kW
- Conditioned rated short-circuit current Iq (EF001444): 120 kA
- Rated short-time withstand current lcw (EF007050): 3 kA
- Suitable for fuses (EF006692): NH2
- Number of poles (EF001391): 3
- With error protection (EF007384): Yes
- Type of electrical connection of main circuit (EF006819): Screw connection
- Equipped with connectors (EF011696): Yes
- Suitable for floor mounting (EF007243): No
- Suitable for front mounting (EF007246): No
- Suitable for busbar mounting (EF007259): Yes
- Type of control element (EF006976): Cover grip
More info
▲General specifications
Product specifications
Standard sealable
Electronic fuse monitoring and EMC (Electromagnetic compatibility) as of IEC 61000-4-5
Electronic fuse monitoring and EMC (Electromagnetic compatibility) as of IEC 61000-4-4
Error protection
- Ambient temperature range: -25 °C - 55 °C
- Operating temperature range: -5 °C - 55 °C
- 400 V (AC-23B)
- 500 V (AC-22B)
- 690 V (AC-21B)
IP2XC (contact protection, XNH installed)
IP3X
IP20 (operating status, XNH installed)
III (230/400 V)
III
1.5 VA
NH with live handle straps
3 LEDs (F1, F2, F3) red
1 NC
> 1 kOhm/V
1 NO
Self-supplied
Test button for relay + LEDs
40 mm x 10 mm
Bolt diameter at flange connection: M10
120 mm² - 240 mm² at clamp-type terminal
95 mm² - 300 mm² (1x) at box terminal
120 mm² - 150 mm² (2x) at double clamp-type terminal
400 A (DC-22B)
400 A (AC-22B)
400 A (AC-23B)
120 kA (500 V)