View larger
XNH00-FCE-S160-BT2 183041 Y7-183041 EATON ELECTRIC NH fuse-switch 3p with lowered box terminal BT2 1,5 95 mm..
XNH00-FCE-S160-BT2
183041
Y7-183041
EATON - MOELLER
1 Pcs.
Connectors > Fuse switch disconnector
Industrial Fuse Bases
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Produced by Eaton Moeller, the XNH00-FCE-S160-BT2 183041 Y7-183041 EATON ELECTRIC NH fuse-switch 3p with lowered box terminal BT2 1,5 95 mm.. functions as an NH fuse-switch configured for busbar integration. These units securely enclose NH fuses to facilitate safe manual switching and dependable circuit protection in commercial and industrial electrical distribution setups. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Version as main switch (EF006981): No
- Version as safety switch (EF006985): No
- Max. rated operation voltage Ue AC (EF007355): 500 V
- Rated permanent current Iu (EF001389): 160 A
- Rated operation power at AC-23, 400 V (EF007027): 0 kW
- Conditioned rated short-circuit current Iq (EF001444): 120 kA
- Rated short-time withstand current lcw (EF007050): 7 kA
- Suitable for fuses (EF006692): NH00
- Number of poles (EF001391): 3
- With error protection (EF007384): Yes
- Type of electrical connection of main circuit (EF006819): Frame clamp
- Equipped with connectors (EF011696): Yes
- Suitable for floor mounting (EF007243): No
- Suitable for front mounting (EF007246): No
- Suitable for busbar mounting (EF007259): Yes
- Type of control element (EF006976): Cover grip
More info
▲General specifications
Product specifications
Electronic fuse monitoring and EMC (Electromagnetic compatibility) as of IEC 61000-4-5
Electronic fuse monitoring and EMC (Electromagnetic compatibility) as of IEC 61000-4-4
Halogen free
Error protection
- Ambient temperature range: -25 °C - 55 °C
- Operating temperature range: -5 °C - 55 °C
- 400 V (AC-23B)
- 500 V (AC-22B)
- 690 V (AC-21B)
- 250 V DC at DC-22B
- 440 V DC at DC-21B
IP10 (handle cover open, XNH installed)
IP3X
IP20 (operating status, XNH installed)
III
III (230/400 V)
Self-supplied
1 NO
1 NC
Test button for relay + LEDs
1 LED green
> 1 kOhm/V
3 LEDs (F1, F2, F3) red
1.5 VA
20 mm x 10 mm
Bolt diameter at flange connection: M8
1.5 mm² - 95 mm² at box terminal
10 mm² - 70 mm² at clamp-type terminal
160 A (AC-23B)
160 A (AC-22B)
160 A
100 kA (690 V)