View larger
XN-322-4AI-PTNI 178772 Y7-178772 EATON ELECTRIC Analog input module 4 analog inputs Pt/Ni/KTY/R with 2-wire ..
XN-322-4AI-PTNI
178772
Y7-178772
EATON - MOELLER
1 Pcs.
Automation > Fieldbus, decentr. periphery - analogue I/O module
Remote I / O Modules XN300
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for modular I/O architectures, this Eaton Moeller XN-322-4AI-PTNI analog input module bridges resistance temperature sensors with control hardware. These modules gather thermal measurement data from industrial equipment and transmit it across the bus system. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Supply voltage AC 50 Hz (EF007532): 0 V
- Supply voltage AC 60 Hz (EF007533): 0 V
- Supply voltage DC (EF007534): 18 V
- Voltage type (supply voltage) (EF002991): DC
- Power consumption (EF000346): 0.3 W
- Input, current (EF003204): No
- Input, voltage (EF003205): No
- Input, resistor (EF003206): Yes
- Input, resistance thermometer (EF003207): Yes
- Input, thermocouple (EF003208): No
- Input signal, configurable (EF003209): Yes
- Resolution of the analogue inputs (EF003575): 16 Bit
- Output, current (EF003212): No
- Output, voltage (EF003213): No
- Output signal configurable (EF003214): No
- Resolution of the analogue outputs (EF003577): 0 Bit
More info
▲General specifications
IEC/EN 61000-6-2
UL File No.: E135462
IEC/EN 61131-2
IEC/EN 61000-6-4
CULus
Features & Functions
Fieldbus connection over separate bus coupler possible
Analog outputs configurable
Input, resistor
Analog inputs configurable
Input signal, configurable
Parameterizable Software input filter
0 - 2500 (Resistance measurement)
-40 - 300 °C (Temperature measurement, KTY84)
0 - 500 (Resistance measurement)
-50 - 150 °C (Temperature measurement, KTY11)
-200 - 850 °C (Temperature measurement, PT100/200/500/1000)
-60 - 250 °C (Temperature measurement, NI100/1000)
-60 - 150 °C (Temperature measurement, NI100/1000)
0 - 250 (Resistance measurement)
0 - 5000 (Resistance measurement)
-200 - 150 °C (Temperature measurement, PT100/200/500/1000)
-55 - 150 °C (Temperature measurement, KTY81)
General
0 mA (typ.), for +5 V power supply (internal), Power supply - Input
NEMA 1
XN300
Ambient conditions, mechanical
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-3
Electro magnetic compatibility
2 kV, Supply cable
10 V/m at 0.08 - 1.0 GHz (according to IEC EN 61000-4-3)
3 V/m at 1.4 - 2 GHz (according to IEC EN 61000-4-3)
40 dB (at 30 - 230 MHz, Class A, radiated, high frequency)
1 kV, Signal cable, unbalanced, EMC
Terminal capacities
0.2 - 1.5 mm², solid, H07V-U
24 - 16 AWG
0.25 - 1.5 mm², with ferrules without plastic collar according to DIN 46228-1 (ferrules crimped gas-tight)
0.25 - 0.75 mm², with ferrules with plastic collar according to DIN 46228-1 (ferrules crimped gas-tight)
Electrical rating
Communication
Push-in spring-cage terminal (plug-in connection), Connection design in TOP direction
Input/Output
Resistance