EATON - MOELLER BP-F-1200/17/3-W BP-F-1200/17/3-W 102343 0002459191 EATON ELECTRIC White floor standing distribution board with three-point t.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

BP-F-1200/17/3-W 102343 0002459191 EATON ELECTRIC White floor standing distribution board with three-point t..

BP-F-1200/17/3-W

102343

0002459191

EATON - MOELLER

1 Pcs.

White floor standing distribution board with three-point turn-lock, W = 1200 mm, H = 1760 mm, D = 300 mm Floor standing distribution board with cam lock, IP30, white, RAL 9016, width 1200 mm, outside height 1760 mm, front plate height 1650 mm, depth of 300 mm, incl. gland plate inserts at the top and bottom, metal door with cam lock, door can be right-hand or left-hand door, if using an MSW assembly configuration, 2 pairs of BPZ-CTS-S corner towers and 1 BPZ-SNAP-MSW-CTS snap fitting element will be additionally required, if using a base frame assembly configuration, 2 BPZ-FPS front plate supports will be additionally required . indoor installation with MSW or mounting towers possible, earthed metal covers, extraordinary stability as a result of welded construction, ample wiring area, variable interior fittings with / without removable mounting frame, well-structured, multilayered design for easily accessible installation: base frame - DIN-rails ... - enclosure

Automation > Enclosure/switchgear cabinet (empty)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Flush-mounting meter cabinet, W=835mm, H=1760mm, 3 meter plates
Flush-mounted metering distribution board, kärnten, distribution board with enclosure and mounting subrack, equipment supplied: wall trough with back plate + door frame + mounting subrack
[

Design verification as per IEC/EN 61439

Technical data for design verification
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890Individual enclosure, flush mounting [PV]
130 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890Individual enclosure, flush mounting [PV]
261 W
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Not relevant to indoor installations.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply to enclosures without lifting aids.
10.2 Strength of materials and parts10.2.6 Mechanical impact
IK07
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
IP30
10.4 Clearances and creepage distances
Is the panel builder's responsibility.
10.5 Protection against electric shock
< 0.1 Ω; meets the product standard's requirements.
10.6 Incorporation of switching devices and components
Is the panel builder's responsibility.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Ui= 440 V AC
10.9 Insulation properties10.9.3 Impulse withstand voltage
4 kV
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Does not apply to metal enclosures.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
Meets the product standard's requirements.
,

Technical data ETIM 7.0

Meter panels (EG000022) / Meter cabinet equipped (EC000262)
Electric engineering, automation, process control engineering / Electrical installation, device / Electrical distribution system (incl. small distribution board) / Meter cabinet equipped ([email protected] [ACN405011])
Model
1-story
Number of meter cabinets
3
Number of TSG-panels
0
Lower connection space
With DIN rails (top hat rails)
Mounting method
Flush mounted (plaster)
Material
Sheet steel
Material
Steel plate
Number of distributor rows
6
Number of fields
1
With mounting plate
No
Degree of protection (IP)
IP30
Width
835 mm
Height
1760 mm
Depth
245 mm
Built-in width
806 mm
Built-in height
1733 mm
Built-in depth
240 mm
]

ETIM for 102343 Cabinets and enclosures (EC000261)
Feature Name Feature Value
Width (EF000008) 1215 mm
Height (EF000040) 1780 mm
Depth (EF000049) 315 mm
Material (EF002169) Steel
Material quality (EF001257) Other
Surface finishing (EF006569) Powder coated
Colour (EF000007) White
RAL-number (EF000116) 9016
Freestanding (EF020363) Yes
Floor standing wall model (EF015208) No
Suitable for wall mounting (EF000664) No
Corner model (EF020814) No
Intermediate mounting (EF022994) No
Couplable (EF001229) No
With mounting plate (EF000118) No
Mounting plate depth-adjustable (EF006054) Yes
Suitable for wall built-in (EF007536) No
Pole fastening (EF009582) No
With door (EF009169) Yes
Number of doors (EF000122) 2
With glazed door (EF001089) No
With ventilation door (EF006279) No
With rear door (EF007381) No
Number of locks (EF000123) 1
With cover (EF007965) No
Transparent cover (EF011401) No
Suitable for metrical mounting (EF005823) Yes
Pitched roof (EF009278) No
Number of connector holes (EF005554) 0
Pre-stamping (EF001039) No
EMC-version (EF001062) Yes
Impact strength (EF004293) IK08
Degree of protection (IP) (EF005474) IP30
Degree of protection (NEMA) (EF011959) Other
Thermal dissipation (Delta T = 20 K) according to IEC/TR 60890 (EF014986) 0 W
Max. permissible load of the enclosure according to IEC 62208 (EF014987) 0 N
Max. permissible load of the door(s) according to IEC 62208 (EF014988) 0 N
Max. permissible load of the mounting plate according to IEC 62208 (EF014989) 0 N

Product Datasheet