Branch strip SVH 400 N, bottom 3p+N Fuse switch-disconnector, 100A, 1Np, 22x58 size The flash function indicates the blowing of fuse link. rated operating voltage 690 VAC, suitable for cylindrical fuse links with utilization class gG (gL), aM, can be sealed, double conductor run possible on both sides

Connectors > Fuse switch disconnector
Modular Switchgear – Others and Accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Eaton Moeller Branch strip SVH 400 N, bottom 3p+N serves as an electrical distribution component used to route and protect power feeds in industrial panel enclosures. These distribution strips help organize complex wiring layouts while providing secure multi-pole connection points.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Version as main switch (EF006981): No
  • Version as safety switch (EF006985): Yes
  • Max. rated operation voltage Ue AC (EF007355): 690 V
  • Rated permanent current Iu (EF001389): 100 A
  • Number of poles (EF001391): 2
  • With error protection (EF007384): No
  • Type of electrical connection of main circuit (EF006819): Screw connection
  • Equipped with connectors (EF011696): No
  • Suitable for floor mounting (EF007243): Yes
  • Suitable for front mounting (EF007246): No
  • Suitable for busbar mounting (EF007259): No
  • Type of control element (EF006976): Rocker lever
  • Motor drive optional (EF007386): No
  • Motor drive integrated (EF006697): No
  • Version as emergency stop installation (EF006959): No
  • Degree of protection (IP), front side (EF003118): IP20

More info

▲
Fuse switch-disconnector, 100A, 1Np, 22x58 size
The flash function indicates the blowing of fuse link. rated operating voltage 690 VAC, suitable for cylindrical fuse links with utilization class gG (gL), aM, can be sealed, double conductor run possible on both sides

Delivery program

For cylindrical fuses
Up to 100 A
Without flashing function
Size
22 x 58
Number of poles
1 + N

Technical data

Electrical
Number of poles
1P
1P+N
2P
3P
3P+N
Rated operating voltage [Ue]
690 V AC
Rated operational current [Ie]
100 A
Rated conditional short-circuit current [Ie]
100
Rated frequency [f]
50 Hz
Utilization category
AC 21 B
Rated impulse withstand voltage [Uimp]
8 kV
Fuse
gG: 9.5, aM: 7 W
Mechanical
Standard front dimension
45 mm
Enclosure height
121 mm
Mounting width
36/per pole mm
Weight
1P 160
1P+N 355
2P 310
3P 480
3P+N 680 g
Mounting
Quick attachment for top-hat rail IEC/EN 60715
Degree of protectionIntegrated
IP20
Terminals
Lift terminals
Terminal capacitiesSolid
4 - 50 mm2
Temperature range
-25 … +60 °C
Specified tightening torque for terminal screwsTightening torque
max. 2.5 Nm
Overvoltage category/pollution degree
-/1
Track resistance
CTI 400

Design verification as per IEC/EN 61439

Rated operational current for specified heat dissipation [In]
100 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
9.5 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+55 °C
0

Technical data ETIM 5.0

Low-voltage industrial components (EG000017) / Fuse switch disconnector (EC001040)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Fuse switch disconnector (ecl@ss8-27-37-14-01 [AKF058009])
Version as switch disconnector compact
Yes
Version as main switch
No
Version as safety switch
Yes
Max. rated operation voltage Ue AC
690 V
Rated permanent current Iu
100 A
Conditioned rated short-circuit current Iq
100 kA
Suitable for fuses
Not applicable
Number of poles
2
With error protection
No
Connection type main current circuit
Screw connection
Suitable for ground mounting
Yes
Suitable for front mounting 4-hole
No
Suitable for busbar mounting
No
Type of control element
Rocker lever
Version as emergency stop installation
No
Degree of protection (IP), front side
IP20

Dimensions


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.