NZM2/3-XUHIV20LK110-130AC 284407 Y7-284407 EATON ELECTRIC Undervoltage release, 110-130VAC +2N/Oem
NZM2/3-XUHIV20LK110-130AC
284407
Y7-284407
EATON - MOELLER
1 Pcs.
Automation > Under voltage coil
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for integration into industrial switchgear, the Eaton Moeller NZM2/3-XUHIV20LK110-130AC functions as an undervoltage release mechanism. It prevents accidental machine startup following a power loss by actively disconnecting the circuit when line voltage drops below safety thresholds.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 110 V
- Rated control supply voltage AC 60 Hz (EF003979): 110 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Type of electric connection (EF003961): Screw connection
- Number of contacts as normally open contact (EF008256): 2
- Number of contacts as normally closed contact (EF008255): 0
- Number of contacts as change-over contact (EF008257): 0
- Delayed (EF001541): No
- Suitable for power circuit breaker (EF005863): No
- Suitable for off-load switch (EF001543): Yes
- Suitable for motor safety switch (EF005826): No
- Suitable for overload relay (EF001545): No
More info
▲General specifications
UL/CSA
RoHS conform
CSA certified
UL listed
UL489
CSA (File No. 22086)
CSA (Class No. 1437-01)
IEC60947
UL (File No. E140305)
CE marking
CSA-C22.2 No. 5-09
Product specifications
- Undervoltage release with 2 early-make auxiliary contacts, e.g., for early-make connection of undervoltage release in main switch applications, as well as for interlock and load shedding circuits.
- For use with emergency-stop devices in connection with an emergency-stop button.
- When the under-voltage trip is switched off, accidental contact with the circuit breaker’s primary contacts is prevented when switched on.
- Early make of auxiliary contacts on switching on and off (manual operation): approx. 20 ms
- Cannot be used in conjunction with NZM...-XR... remote operator.
- Undervoltage releases cannot be installed simultaneously with NZM...-XHIV... early-make auxiliary contact or NZM...-XA... shunt release.
NZM2(-4), N(S)2(-4)
Coil terminals with 3 m of loose connection cables
0.75 mm² - 2.5 mm² (2x) at shunt release with ferrule
18 - 14 AWG (1x) for undervoltage releases, off-delayed
18 - 14 AWG (2x) for undervoltage releases, off-delayed
18 - 14 AWG (1x) at shunt release
0.75 mm² - 2.5 mm² (2x) for undervoltage releases, off-delayed with ferrule
0.75 mm² - 2.5 mm² (1x) for undervoltage releases, off-delayed with ferrule
18 - 14 AWG (2x) at shunt release
1.5 VA (sealing AC)
130 V AC