View larger
PKE-XTUA-1,2 121727 Y7-121727 EATON ELECTRIC Trip block, 0.3-1.2A, networkable, motor protection
PKE-XTUA-1,2
121727
Y7-121727
EATON - MOELLER
1 Pcs.
Automation > Tripping bloc for power circuit-breaker
Electronic Circuit Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller trip block, 0.3-1.2A, networkable, motor protection modules act as precision overcurrent detection units within industrial electrical distribution panels, preventing thermal damage to connected machinery. These devices safeguard electric motors against phase loss and overload conditions by interrupting the circuit during fault events. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Manufacturer: Eaton Moeller
- Manufacturer part number: PKE-XTUA-1,2
- Catalogue code: 121727
- Catalogue title: PKE-XTUA-1,2 121727 Y7-121727 EATON ELECTRIC Trip block, 0.3-1.2A, networkable, motor protection
- Product description: General specifications Product Name Eaton Moeller® series PKE Trip block Catalog Number 121727 Model Code PKE-XTUA-1,2 EAN 4015081195374 Product Length/Depth 41.6 mm Product Height 64.2 mm Product Width 45 mm Product Wei
- Manufacturer summary: Trip block, 0.3-1.2A, networkable, motor protection PKE-XTUA-1,2 Eaton Moeller® series PKE Trip block, 0.3 - 1.2 A, Motor protection, Connection to SmartWire-DT: yes, For use with: PKE12 basic device
More info
▲General specifications
VDE 0660
CSA Class No.: 3211-05
IEC/EN 60947-4-1
CSA
UL Category Control No.: NLRV
IEC/EN 60947
CSA-C22.2 No. 14-10
UL
UL 508
CE
UL File No.: E36332
Features & Functions
Motor protection for heavy starting duty
Overload release
General
500 (Class 5) AC-4 cycle operation, Main conducting paths
Note: Going below the minimum current flow time can cause overheating of the load (motor).
900 (Class 15) AC-4 cycle operation, Main conducting paths
1000 (Class 20) AC-4 cycle operation, Main conducting paths
For all combinations with an SWD activation, you need not adhere to the minimum current flow times and minimum cut-out periods.
Terminals: IP00
-5 - 40 °C to IEC/EN 60947, VDE 0660
Ambient conditions, mechanical
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Electrical rating
Short-circuit rating
± 20% tolerance, Trip blocks
Trip block fixed 15.5 x Ir
Switching capacity
Magnet system
Communication
Yes
In conjunction with PKE-SWD-SP SmartWire DT PKE module