View larger
PKZM0-20-T 088918 Y7-88918 EATON ELECTRIC Transformer-protective circuit-breaker, 3p, Ir 16-20A, screw conne..
PKZM0-20-T
088918
Y7-88918
EATON - MOELLER
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Circuit Breakers PKZ
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A transformer-protective circuit-breaker serves as a dedicated switching and protection device primarily used in industrial control panels to protect control transformers against overload and short-circuit currents. It ensures reliable operational safety for specialized inductive loads.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated permanent current Iu (EF001389): 20 A
- Rated voltage (EF003977): 690 V
- Overload release current setting (EF002336): 16 A
- Adjustment range undelayed short-circuit release (EF007131): 380 A
- Power loss (EF005387): 5.68 W
- Device construction (EF008240): Built-in device fixed built-in technique
- Integrated earth fault protection (EF007296): No
- Type of electrical connection of main circuit (EF006819): Screw connection
- Suitable for DIN rail (top hat rail) mounting (EF007250): Yes
- DIN rail (top hat rail) mounting optional (EF008904): Yes
- With switched-off indicator (EF007006): Yes
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Type of control element (EF006976): Rotating button
- Complete device with protection unit (EF008906): Yes
- Motor drive integrated (EF006697): No
More info
▲General specifications
VDE 0660
Features & Functions
Phase-failure sensitivity (according to IEC/EN 60947-4-1, VDE 0660 Part 102)
Transformer protection
General
Also motors with efficiency class IE3
-5 - 40 °C to IEC/EN 60947, VDE 0660
-25 - 55 °C, Operating range
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
2 x (1 - 6) mm², ferrule to DIN 46228
1 x (1 - 6) mm²
1.7 Nm, Screw terminals, Main cable
Electrical rating
Short-circuit rating
10 kA, 600 V High Fault, CB, SCCR (UL/CSA) with 125 A, 600 V High Fault, CB, SCCR (UL/CSA)
18 kA, 600 V High Fault, Fuse with CL, SCCR (UL/CSA) with 600 A, 600 V High Fault, Fuse with CL, SCCR (UL/CSA)
18 kA, 600 V High Fault, CB with CL, SCCR (UL/CSA) with 600 A, 600 V High Fault, CB with CL, SCCR (UL/CSA)
18 kA, 480 V High Fault, CB, SCCR (UL/CSA) with 600 A, 480 V High Fault, CB, SCCR (UL/CSA)
18 kA, 480 V High Fault, Fuse, SCCR (UL/CSA) with 600 A, 480 V High Fault, Fuse, SCCR (UL/CSA)
± 20% tolerance, Trip blocks
Basic device, fixed 20 x Iu, Trip Blocks