Request QuoteProduct Overview
XVS-440-57MPI-1-10 by Eaton Moeller serves as a dependable touch panel for machine control systems requiring intuitive operator interfaces. Human-machine interface devices are essential for monitoring processes, managing alarms, and fine-tuning automated production equipment.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product range: XVS400 5.7"
- Function: HMI-PLC (PLC retrofitted by user)
- Display - Type: Color display, CSTN
- Touch-technology: Infra-red touch
- Number of colours: 256 colors
- Resolution: QVGA, 320 x 240 Pixel
- Portrait format: yes
- Screen diagonal: 5.7 Inch, Metal enclosure and front plate
- Operating system: Windows CE (license required), CompactFlash card required
- PLC-licence: Can be fitted by user with article no. 140389 LIC-PLC-MXP-SMALL
- Front type: Standard front with standard membrane, Laminated safety glass, non-reflective
- Utilization: Flush mounting
- Memory card automation: required, see Accessories -> Memory cards
- Pluggable communication cards (optional): no
- Heat dissipation: 19 W, Degree of protection (IEC/EN 60529, EN50178; UL/CSA Type: - Dimensions Link to sheet catalogue Dimensions
More info
▲Delivery program
USB device
RS232
Profibus/MPI
UL508, cUL approvals
PLC function can be fitted by user
Communications scope can be fitted by user with licenses
320 x 240 Pixel
CompactFlash card required
1 x RS232
1 x PROFIBUS/MPI
1 x USB host
1 x USB device
Laminated safety glass, non-reflective
Technical data
320 x 240 Pixel
dimmable via software
47 x 31 logic channels
Flash (can be used for data backup): approx. 1.5 MByte available
NVRAM (retained data): approx. 32 KByte available
EPAM
XSOFT-CODESYS-2
XSOFT-CODESYS-3
XSOFT-CODESYS-3
CompactFlash card required
1 x RS232
1 x PROFIBUS/MPI
1 x USB host
1 x USB device
Absolute with ripple: 19.2-30.0 V DC
35 V DC for a duration of < 100 ms
2 ms from undervoltage (20.4 V DC) ms
16 W for basic device + 3 W for USB module
Laminated safety glass, non-reflective
EN 61000-6-2
EN 61000-6-3
EN 61000-6-4
EN 61131-2
EN 61131-2
UL 60950
Design verification as per IEC/EN 61439
Technical data ETIM 6.0
Approvals
Proper bonding to the end-product main protective earthing termination is: Required
The following end-product enclosures are required: Fire, Electrical
The unit must be supplied via a SELV source.
The provided Ethernet Connection is only allowed to connect to inhouse networks.