DILET11-30-A
048878
EATON - MOELLER
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Product range | DILET timing relays | ||
The basic function of | Relay timer | ||
The function | In retarded | ||
| Sets the timing function | |||
Number of switching contacts | 1 | ||
Time Range | 1.5 - 30 s | ||
Time Range | 1.5 - 30 s | ||
Rated Operating Current | |||
AC-11 | |||
230 V | Iand | One | 3 |
380 V 400 V 415 V | Iand | One | 3 |
AC-15 | |||
220 V 230 V 240 V | Iand | One | 3 |
Voltage range of | ULN | V | 24 - 240 VAC, 50/60 Hz 24 - 240 V DC |
Wide | mm | 45 | |
| Terminal of the brand according to EN 50042 | |||
| General | |||
Standards | The IEC/EN 61812 standard VDE 0435 | ||
Life expectancy, mechanics | |||
AC operated | The operations of | x 106 | 30 |
DC operated | The operations of | x 106 | 30 |
Climatic correction | Moist, Constant Heat, IEC 60068-2-78 Moist, cyclic heat, IEC 60068-2-30 | ||
Ambient Temperature | |||
Open | °C | -20 - +60 | |
Closed | °C | - 20 - + 45 | |
Mounting position | As required | ||
Shock Resistance Mechanics (IEC/EN 60068-2-27) | |||
Sinusoidal half shock, 20 ms | g | ||
Make contact | g | 4 | |
Degree of protection | |||
Terminals | IP20 | ||
Weight | kg | 0.09 | |
Capacity terminal | mm2 | ||
Solid | mm2 | 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) | |
Flexible with cap | mm2 | 1 x (0.75 - 1.5) 2 x (0.75 - 1.5) | |
Solid or braided | AWG | 1 x (18 - 14) | |
| Contacts | |||
Rated Supported Pulse Voltage | Uimp | V AC | 6000 |
Overvoltage category/degree of contamination | III/2 | ||
Rated insulation voltage | UI | V AC | 600 |
Rated Operating Voltage | Uand | V AC | 440 |
Safety insulation according to EN 61140 | |||
between coil and auxiliary contacts | V AC | 250 | |
between auxiliary contacts | V AC | 250 | |
The manufacturing capacity of | |||
Nah, no way | One | 48 | |
AC-15 cos φ = 0.3 220 V | One | 50 | |
DC-11 L/R 40 ms | x Iand | 1.1 | |
Breaking capacity | |||
Nah, no way | One | 3 | |
Nah, no way | One | 3 | |
DC-11 L/R 40 ms | x Iand | 1.1 | |
Rated Operating Current | Iand | One | |
CA--14 | |||
440 V | Iand | One | 3 |
AC-15 | |||
220 V 230 V 240 V | Iand | One | 3 |
DC-11 | |||
Note | Decision Making and Breaking Conditions for DC13, Time Constant as Indicated | ||
L/R max. 15 ms | One | ||
24 V | Iand | One | 1.5 |
L/R max. 50 ms | One | 1.2 | |
Conv. Thermal Current | ITh | One | 6 |
Solderless Short Circuit Rating | |||
Note | When powered directly from the mains or transformer > 1000 VA | ||
Max. fuse, make contacts | One gG/gL | 6 | |
Max. fuse, break contacts | One gG/gL | 6 | |
| Magnet Systems | |||
Rated Operating Voltage | Uand | V | |
AC | 24 - 240 | ||
DC | 24 - 240 | ||
AC Rated Frequency | Hz | 47 - 63 | |
The tolerance of AC operated min. | x Uc | 0.85 | |
The tolerance of AC operated max. | x Uc | 1.1 | |
DC tolerance operated min. | x Uc | 0.7 | |
The DC tolerance operated max. | x Uc | 1.1 | |
Tension tolerance | x Uc | ||
Voltage pick-up | x Us | ||
Min. AC voltage pick-up, operated | x Uc | 0.85 | |
AC voltage pick-up operated, max. | x Uc | 1.1 | |
DC voltage operated pick-up, min. | x Uc | 0.7 | |
Max. pick-up, DC operated | x Uc | 1.1 | |
Energy consumption | |||
Pick-up AC | GOES | 2 | |
AC Sealing | GOES | 2 | |
Pick-up DC | W | 1.8 | |
DC Sealing | W | 1.8 | |
Duty Factor | % DF | 100 | |
Maximum Operating Frequency | Ops/h | 4000 | |
Minimal Command Time | |||
AC | Ms | 50 | |
DC | Ms | 30 | |
Repeat Accuracy (Deviation) | % | ||
Technical data for design verification | |||
Rated operating current specified in heat dissipation | In | One | 6 |
Heat dissipation per pole, dependent on the current | Pgrapevine | W | 0.9 |
Heat dissipation equipment, dependent on the current | Pgrapevine | W | 0 |
Static heat dissipation, not dependent on current | Pvs | W | 1.8 |
Heat dissipation capacity | PDiss | W | 0 |
Ambient operating temperature min. | °C | -20 | |
Operating environment max. temperature | °C | 60 | |
IEC/EN 61439 Design Verification | |||
10.2 Strength of Materials and Parts | |||
10.2.2 Corrosion Resistance | Complies with the product standard. | ||
10.2.3.1 Verification of the thermal stability of enclosures | Complies with the product standard. | ||
10.2.3.2 Verification of the Strength of Normal Heat Insulation Materials | Complies with the product standard. | ||
10.2.3.3 Verification of the resistance of insulating materials to abnormal heat and fire due to internal electrical effects | Complies with the product standard. | ||
10.2.4 Ultraviolet (UV) resistance | Complies with the product standard. | ||
10.2.5 Lifting | It is not applied, since all the cells must be evaluated. | ||
10.2.6 Mechanical Impact | It is not applied, since all the cells must be evaluated. | ||
10.2.7 Registrations | Complies with the product standard. | ||
10.3 Degree of protection of the ASSEMBLIES | It is not applied, since all the cells must be evaluated. | ||
10.4 Separations and Creepage Distances | Complies with the product standard. | ||
10.5 Protection against electric shock | It is not applied, since all the cells must be evaluated. | ||
10.6 The Incorporation of Switching Devices and Components | It is not applied, since all the cells must be evaluated. | ||
10.7 Internal Electrical Circuits and Connections | It is the panel of the generator of responsibility. | ||
10.8 Connections for External Conductors | It is the panel of the generator of responsibility. | ||
10.9 Insulation properties | |||
10.9.2 Power Electric Force Frequency | It is the panel of the generator of responsibility. | ||
10.9.3 Impulse Withstand Voltage | It is the panel of the generator of responsibility. | ||
10.9.4 Testing of Insulation Boxes | It is the panel of the generator of responsibility. | ||
10.10 Temperature Rise | The builder panel is responsible for the increase in the calculation temperature. Eaton will provide data heat dissipation for the devices. | ||
10.11 Short Circuit Rating | It is the panel of the generator of responsibility. The cell specifications must be observed. | ||
10.12 Electromagnetic Compatibility | It is the panel of the generator of responsibility. The cell specifications must be observed. | ||
10.13 Mechanical Function | The device meets the requirements, provided that the information on the instruction sheet (IL) is observed. | ||
| Relays (EG000019) / Relay Timer (EC001439) | |||
| Electrical Engineering, Automation, Process Control, Engineering Low Voltage Switch Technology/Relay and Socket/Timed Relay ([email protected] [AKF092010]) | |||
Electrical Connection Type | Connecting screw | ||
Delay function in energization | Yes | ||
Disable delay function | No | ||
Floating contact function in energization | No | ||
Floating contact function on deactivation | No | ||
The star-delta function | No | ||
The pulse function of the conformation of | No | ||
Flashing function, starting with pause, fixed time | No | ||
Intermittent function, starting with pulse, fixed time | No | ||
The clock function, starting with the pause, the variable | No | ||
The clock function, starting with the pulse, the variable | No | ||
With socket of | No | ||
Remote operation possible | No | ||
Suitable for remote control only | No | ||
Pluggable in auxiliary contact block | No | ||
Rated Supply Voltage Control Us AC 50HZ | V | 24 - 240 | |
Rated Supply Voltage Control Us AC 60HZ | V | 24 - 240 | |
Rated Supply Voltage Control with Us at DC | V | 24 - 240 | |
Voltage Drive Type | AC/DC | ||
Time Range | s | 1.5 - 30 | |
Number of outputs, undelayed, normally closed contact | 0 | ||
Number of Outputs, Undelayed, Normally Open Contact | 0 | ||
Number of Outputs, Undelayed, Switched Contact | 0 | ||
Number of departures, delayed, normally closed contact | 0 | ||
Number of departures, delayed, normally open contact | 0 | ||
Number of departures, delayed, change of contact | 1 | ||
Outputs, reversible delayed/undelayed | No | ||
With the semiconductor output. | No | ||
Wide | mm | 45 | |
Height | mm | 58 | |
Depth | mm | 52 | |
| Feature Name | Feature Value |
|---|---|
| Type of electric connection (EF003961) | Screw connection |
| Complete with socket (EF003359) | No |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| Suitable for front mounting (EF020288) | No |
| Pluggable on auxiliary contact block (EF006952) | No |
| Function delay-on energization (EF003374) | Yes |
| Function delay on de-energization (EF003401) | No |
| Function floating contact on energization (EF003378) | No |
| Function floating contact on de-energization (EF003402) | No |
| Function star-delta (EF003380) | No |
| Function pulse shaping (EF003403) | No |
| Function flashing, starting with pause, fixed time (EF003363) | No |
| Function flashing, starting with pulse, fixed time (EF003364) | No |
| Clock function, starting with pause, variable (EF003365) | No |
| Clock function, starting with pulse, variable (EF003366) | No |
| Time range (EF003384) | 1.5 s |
| Remote operation possible (EF003361) | No |
| Suitable as remote control (EF003362) | No |
| Rated control supply voltage AC 50 Hz (EF003978) | 24 V |
| Rated control supply voltage AC 60 Hz (EF003979) | 24 V |
| Rated control supply voltage DC (EF003980) | 24 V |
| Voltage type for actuating (EF008242) | AC/DC |
| Number of outputs, undelayed, normally closed contact (EF006835) | 0 |
| Number of outputs, undelayed, normally open contact (EF006836) | 0 |
| Number of outputs, undelayed, change-over contact (EF006837) | 0 |
| Number of outputs, delayed, normally closed contact (EF006838) | 0 |
| Number of outputs, delayed, normally open contact (EF006839) | 0 |
| Number of outputs, delayed, change-over contact (EF006840) | 1 |
| Outputs, reversible delayed/undelayed (EF006988) | No |
| With semiconductor output (EF003373) | No |
| Degree of protection (IP) (EF005474) | IP20 |
| Width (EF000008) | 45 mm |
| Height (EF000040) | 58 mm |
| Depth (EF000049) | 52 mm |