View larger
DILET11-30-A 048878 EATON ELECTRIC XTMT6A30S11B DILET 11-30-A multifunction timer
DILET11-30-A
048878
EATON - MOELLER
1 Pcs.
Automation > Timer relay
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller DILET11-30-A multifunction timer governs precise time delays and switching sequences in industrial automation and electrical distribution systems. Timers of this category regulate motor starts, conveyor intervals, and automated manufacturing cycles safely and reliably.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- 230 V: I and
- 380 V 400 V 415 V: I and
- 220 V 230 V 240 V: I and
- Voltage range of: U LN
- AC operated: The operations of
- DC operated: The operations of
- Contacts Rated Supported Pulse Voltage: U imp
- Rated insulation voltage: U I
- Rated Operating Voltage: U and
- Rated Operating Current: I and
- 440 V: I and
- 220 V 230 V 240 V: I and
- 24 V: I and
- Conv. Thermal Current: I Th
- Magnet Systems Rated Operating Voltage: U and
- Rated operating current specified in heat dissipation: I n
More info
▲Product range | DILET timing relays | ||
The basic function of | Relay timer | ||
The function | In retarded | ||
| Sets the timing function | |||
Number of switching contacts | 1 | ||
Time Range | 1.5 - 30 s | ||
Time Range | 1.5 - 30 s | ||
Rated Operating Current | |||
AC-11 | |||
230 V | Iand | One | 3 |
380 V 400 V 415 V | Iand | One | 3 |
AC-15 | |||
220 V 230 V 240 V | Iand | One | 3 |
Voltage range of | ULN | V | 24 - 240 VAC, 50/60 Hz 24 - 240 V DC |
Wide | mm | 45 | |
| Terminal of the brand according to EN 50042 | |||
| General | |||
Standards | The IEC/EN 61812 standard VDE 0435 | ||
Life expectancy, mechanics | |||
AC operated | The operations of | x 106 | 30 |
DC operated | The operations of | x 106 | 30 |
Climatic correction | Moist, Constant Heat, IEC 60068-2-78 Moist, cyclic heat, IEC 60068-2-30 | ||
Ambient Temperature | |||
Open | °C | -20 - +60 | |
Closed | °C | - 20 - + 45 | |
Mounting position | As required | ||
Shock Resistance Mechanics (IEC/EN 60068-2-27) | |||
Sinusoidal half shock, 20 ms | g | ||
Make contact | g | 4 | |
Degree of protection | |||
Terminals | IP20 | ||
Weight | kg | 0.09 | |
Capacity terminal | mm2 | ||
Solid | mm2 | 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) | |
Flexible with cap | mm2 | 1 x (0.75 - 1.5) 2 x (0.75 - 1.5) | |
Solid or braided | AWG | 1 x (18 - 14) | |
| Contacts | |||
Rated Supported Pulse Voltage | Uimp | V AC | 6000 |
Overvoltage category/degree of contamination | III/2 | ||
Rated insulation voltage | UI | V AC | 600 |
Rated Operating Voltage | Uand | V AC | 440 |
Safety insulation according to EN 61140 | |||
between coil and auxiliary contacts | V AC | 250 | |
between auxiliary contacts | V AC | 250 | |
The manufacturing capacity of | |||
Nah, no way | One | 48 | |
AC-15 cos φ = 0.3 220 V | One | 50 | |
DC-11 L/R 40 ms | x Iand | 1.1 | |
Breaking capacity | |||
Nah, no way | One | 3 | |
Nah, no way | One | 3 | |
DC-11 L/R 40 ms | x Iand | 1.1 | |
Rated Operating Current | Iand | One | |
CA--14 | |||
440 V | Iand | One | 3 |
AC-15 | |||
220 V 230 V 240 V | Iand | One | 3 |
DC-11 | |||
Note | Decision Making and Breaking Conditions for DC13, Time Constant as Indicated | ||
L/R max. 15 ms | One | ||
24 V | Iand | One | 1.5 |
L/R max. 50 ms | One | 1.2 | |
Conv. Thermal Current | ITh | One | 6 |
Solderless Short Circuit Rating | |||
Note | When powered directly from the mains or transformer > 1000 VA | ||
Max. fuse, make contacts | One gG/gL | 6 | |
Max. fuse, break contacts | One gG/gL | 6 | |
| Magnet Systems | |||
Rated Operating Voltage | Uand | V | |
AC | 24 - 240 | ||
DC | 24 - 240 | ||
AC Rated Frequency | Hz | 47 - 63 | |
The tolerance of AC operated min. | x Uc | 0.85 | |
The tolerance of AC operated max. | x Uc | 1.1 | |
DC tolerance operated min. | x Uc | 0.7 | |
The DC tolerance operated max. | x Uc | 1.1 | |
Tension tolerance | x Uc | ||
Voltage pick-up | x Us | ||
Min. AC voltage pick-up, operated | x Uc | 0.85 | |
AC voltage pick-up operated, max. | x Uc | 1.1 | |
DC voltage operated pick-up, min. | x Uc | 0.7 | |
Max. pick-up, DC operated | x Uc | 1.1 | |
Energy consumption | |||
Pick-up AC | GOES | 2 | |
AC Sealing | GOES | 2 | |
Pick-up DC | W | 1.8 | |
DC Sealing | W | 1.8 | |
Duty Factor | % DF | 100 | |
Maximum Operating Frequency | Ops/h | 4000 | |
Minimal Command Time | |||
AC | Ms | 50 | |
DC | Ms | 30 | |
Repeat Accuracy (Deviation) | % | ||
Technical data for design verification | |||
Rated operating current specified in heat dissipation | In | One | 6 |
Heat dissipation per pole, dependent on the current | Pgrapevine | W | 0.9 |
Heat dissipation equipment, dependent on the current | Pgrapevine | W | 0 |
Static heat dissipation, not dependent on current | Pvs | W | 1.8 |
Heat dissipation capacity | PDiss | W | 0 |
Ambient operating temperature min. | °C | -20 | |
Operating environment max. temperature | °C | 60 | |
IEC/EN 61439 Design Verification | |||
10.2 Strength of Materials and Parts | |||
10.2.2 Corrosion Resistance | Complies with the product standard. | ||
10.2.3.1 Verification of the thermal stability of enclosures | Complies with the product standard. | ||
10.2.3.2 Verification of the Strength of Normal Heat Insulation Materials | Complies with the product standard. | ||
10.2.3.3 Verification of the resistance of insulating materials to abnormal heat and fire due to internal electrical effects | Complies with the product standard. | ||
10.2.4 Ultraviolet (UV) resistance | Complies with the product standard. | ||
10.2.5 Lifting | It is not applied, since all the cells must be evaluated. | ||
10.2.6 Mechanical Impact | It is not applied, since all the cells must be evaluated. | ||
10.2.7 Registrations | Complies with the product standard. | ||
10.3 Degree of protection of the ASSEMBLIES | It is not applied, since all the cells must be evaluated. | ||
10.4 Separations and Creepage Distances | Complies with the product standard. | ||
10.5 Protection against electric shock | It is not applied, since all the cells must be evaluated. | ||
10.6 The Incorporation of Switching Devices and Components | It is not applied, since all the cells must be evaluated. | ||
10.7 Internal Electrical Circuits and Connections | It is the panel of the generator of responsibility. | ||
10.8 Connections for External Conductors | It is the panel of the generator of responsibility. | ||
10.9 Insulation properties | |||
10.9.2 Power Electric Force Frequency | It is the panel of the generator of responsibility. | ||
10.9.3 Impulse Withstand Voltage | It is the panel of the generator of responsibility. | ||
10.9.4 Testing of Insulation Boxes | It is the panel of the generator of responsibility. | ||
10.10 Temperature Rise | The builder panel is responsible for the increase in the calculation temperature. Eaton will provide data heat dissipation for the devices. | ||
10.11 Short Circuit Rating | It is the panel of the generator of responsibility. The cell specifications must be observed. | ||
10.12 Electromagnetic Compatibility | It is the panel of the generator of responsibility. The cell specifications must be observed. | ||
10.13 Mechanical Function | The device meets the requirements, provided that the information on the instruction sheet (IL) is observed. | ||
| Relays (EG000019) / Relay Timer (EC001439) | |||
| Electrical Engineering, Automation, Process Control, Engineering Low Voltage Switch Technology/Relay and Socket/Timed Relay ([email protected] [AKF092010]) | |||
Electrical Connection Type | Connecting screw | ||
Delay function in energization | Yes | ||
Disable delay function | No | ||
Floating contact function in energization | No | ||
Floating contact function on deactivation | No | ||
The star-delta function | No | ||
The pulse function of the conformation of | No | ||
Flashing function, starting with pause, fixed time | No | ||
Intermittent function, starting with pulse, fixed time | No | ||
The clock function, starting with the pause, the variable | No | ||
The clock function, starting with the pulse, the variable | No | ||
With socket of | No | ||
Remote operation possible | No | ||
Suitable for remote control only | No | ||
Pluggable in auxiliary contact block | No | ||
Rated Supply Voltage Control Us AC 50HZ | V | 24 - 240 | |
Rated Supply Voltage Control Us AC 60HZ | V | 24 - 240 | |
Rated Supply Voltage Control with Us at DC | V | 24 - 240 | |
Voltage Drive Type | AC/DC | ||
Time Range | s | 1.5 - 30 | |
Number of outputs, undelayed, normally closed contact | 0 | ||
Number of Outputs, Undelayed, Normally Open Contact | 0 | ||
Number of Outputs, Undelayed, Switched Contact | 0 | ||
Number of departures, delayed, normally closed contact | 0 | ||
Number of departures, delayed, normally open contact | 0 | ||
Number of departures, delayed, change of contact | 1 | ||
Outputs, reversible delayed/undelayed | No | ||
With the semiconductor output. | No | ||
Wide | mm | 45 | |
Height | mm | 58 | |
Depth | mm | 52 | |