View larger
DILM32-XTEY20(RA24) 101446 Y7-101446 EATON ELECTRIC Timer module, 24VAC/DC, 1-30s, star-delta
DILM32-XTEY20(RA24)
101446
Y7-101446
EATON - MOELLER
1 Pcs.
Automation > Timer block
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller designed the DILM32-XTEY20(RA24) star-delta timer module to manage automatic transition phases in large electric motor starters, reducing initial inrush current. Such specialized timing modules are vital in heavy industrial applications to protect mechanical drives and electrical networks during startup. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Setting time (EF005922): 1 s
- Number of contacts as normally open contact (EF008256): 2
- Number of contacts as normally closed contact (EF008255): 0
- Number of contacts as change-over contact (EF008257): 0
- Operating principle (EF004139): Electronic
More info
▲General specifications
DIN EN 61812
UL
UL 508
UL File No.: E29184
VDE 0660
IEC/EN 60947
CE
CSA
CSA-C22.2 No. 14-05
IEC/EN 60947-4-1
CSA File No.: 012528
UL Category Control No.: NKCR
Features & Functions
General
50 ms, On-delayed
3,000,000 Operations (AC operated)
3600 Operations/h
Ambient conditions, mechanical
6 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
2 x (0.75 - 1.5) mm²
1 x (0.75 - 2.5) mm²
2, Terminal screw, Pozidriv screwdriver
Electrical Rating
0.1 A at 220 V, DC-13 L/R - 50 ms (with 1 contact in series)
1 A at 24 V, DC-13 L/R - 50 ms (with 1 contact in series)
1 A at 24 V, DC-13 L/R - 300 ms (with 1 contact in series)
3 A at AC-15, 220 V 230 V 240 V
0.2 A at 110 V, DC-13 L/R - 300 ms (with 1 contact in series)
0.2 A at 60 V, DC-13 L/R - 50 ms (with 1 contact in series)
0.2 A at 60 V, DC-13 L/R - 300 ms (with 1 contact in series)
0.1 A at 220 V, DC-13 L/R - 300 ms (with 1 contact in series)
Short-circuit rating
125 A, max. Fuse, SCCR (UL/CSA)
5 kA, SCCR (UL/CSA)
50/32 A, max. CB, SCCR (UL/CSA)
125/70 A, Class J, max. Fuse, SCCR (UL/CSA)
10/65 kA, CB, SCCR (UL/CSA)
50/32 A, max. CB, SCCR (UL/CSA)
10/100 kA, Fuse, SCCR (UL/CSA)
125/125 A, Class J, max. Fuse, SCCR (UL/CSA)
Conventional thermal current
Switching capacity
5 A, 240 V AC, (UL/CSA)
R300, DC operated (UL/CSA)
Magnet system
0.85 - 1.1 V AC x Uc
Contacts
Safety
250 V AC, Between auxiliary contacts, According to EN 61140