View larger
DILM32-XTED11-10(RA24) 104943 Y7-104943 EATON ELECTRIC Timer module, 24VAC/DC, 0.5-10s, off-delayed
DILM32-XTED11-10(RA24)
104943
Y7-104943
EATON - MOELLER
1 Pcs.
Automation > Timer block
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller timer module with off-delayed switching functions (DILM32-XTED11-10(RA24)) facilitates controlled circuit de-energization in industrial motor control systems. These accessory units attach directly to contactors to introduce precise drop-out delays, preventing operational faults caused by immediate power losses.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Switching function (EF000189): Time-delay dropped out
- Setting time (EF005922): 0.5 s
- Number of contacts as normally open contact (EF008256): 1
- Number of contacts as normally closed contact (EF008255): 1
- Number of contacts as change-over contact (EF008257): 0
- Operating principle (EF004139): Electronic
More info
▲General specifications
UL
CSA-C22.2 No. 14-05
DIN EN 61812
UL 508
CE
CSA
CSA File No.: 012528
IEC/EN 60947
UL Category Control No.: NKCR
VDE 0660
CSA Class No.: 3211-03
IEC/EN 60947-4-1
Features & Functions
General
200 ms, Off-delayed
3,000,000 Operations (AC operated)
360 mechanical Operations/h
Ambient conditions, mechanical
6 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Climatic environmental conditions
Damp heat, cyclic, to IEC 60068-2-30
Terminal capacities
2 x (0.75 - 1.5) mm²
1 x (0.75 - 2.5) mm²
0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver
Electrical Rating
3 A at AC-15, 220 V 230 V 240 V
0.1 A at 220 V, DC-13 L/R - 300 ms (with 1 contact in series)
0.2 A at 60 V, DC-13 L/R - 50 ms (with 1 contact in series)
1 A at 24 V, DC-13 L/R - 300 ms (with 1 contact in series)
1 A at 24 V, DC-13 L/R - 50 ms (with 1 contact in series)
0.2 A at 110 V, DC-13 L/R - 50 ms (with 1 contact in series)
0.2 A at 60 V, DC-13 L/R - 300 ms (with 1 contact in series)
0.2 A at 110 V, DC-13 L/R - 300 ms (with 1 contact in series)
Short-circuit rating
5 kA, SCCR (UL/CSA)
125 A, max. Fuse, SCCR (UL/CSA)
10/100 kA, Fuse, SCCR (UL/CSA)
10/65 kA, CB, SCCR (UL/CSA)
50/32 A, max. CB, SCCR (UL/CSA)
10/100 kA, Fuse, SCCR (UL/CSA)
125/125 A, Class J, max. Fuse, SCCR (UL/CSA)
10/22 kA, CB, SCCR (UL/CSA)
Conventional thermal current
Switching capacity
5 A, 240 V AC, (UL/CSA)
R300, DC operated (UL/CSA)
Magnet system
0.7 - 1.2 V DC x Uc
Contacts
Safety
250 V AC, Between coil and auxiliary contacts, According to EN 61140