DILM32-XTED11-1(RA24) 105210 Y7-105210 EATON ELECTRIC Timer module, 24VAC/DC, 0.05-1s, off-delayed
DILM32-XTED11-1(RA24)
105210
Y7-105210
EATON - MOELLER
1 Pcs.
Automation > Timer block
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller DILM32-XTED11-1(RA24) 105210 Y7-105210 EATON ELECTRIC Timer module, 24VAC/DC, 0.05-1s, off-delayed attaches directly to compatible motor control contactors to facilitate off-delay timing functions in electrical power systems. These auxiliary modules are widely used in industrial automation to manage safe shutdown sequences and prevent premature gear wear. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Switching function (EF000189): Time-delay dropped out
- Setting time (EF005922): 0.05 s
- Number of contacts as normally open contact (EF008256): 1
- Number of contacts as normally closed contact (EF008255): 1
- Number of contacts as change-over contact (EF008257): 0
- Operating principle (EF004139): Electronic
More info
▲General specifications
CE
CSA
IEC/EN 60947
IEC/EN 60947-4-1
UL 508
UL Category Control No.: NKCR
VDE 0660
UL
CSA File No.: 012528
CSA-C22.2 No. 14-05
DIN EN 61812
UL File No.: E29184
Features & Functions
General
50 ms, On-delayed
3,000,000 Operations (DC operated)
3600 Operations/h
Ambient conditions, mechanical
6 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
1 x (0.75 - 1.5) mm²
2 x (0.75 - 1.5) mm²
2, Terminal screw, Pozidriv screwdriver
Electrical Rating
0.1 A at 220 V, DC-13 L/R - 50 ms (with 1 contact in series)
0.2 A at 110 V, DC-13 L/R - 50 ms (with 1 contact in series)
1 A at 24 V, DC-13 L/R - 300 ms (with 1 contact in series)
0.1 A at 220 V, DC-13 L/R - 300 ms (with 1 contact in series)
0.2 A at 60 V, DC-13 L/R - 50 ms (with 1 contact in series)
3 A at AC-15, 220 V 230 V 240 V
0.2 A at 60 V, DC-13 L/R - 300 ms (with 1 contact in series)
0.2 A at 110 V, DC-13 L/R - 300 ms (with 1 contact in series)
Short-circuit rating
125 A, max. CB, SCCR (UL/CSA)
125 A, max. Fuse, SCCR (UL/CSA)
50/32 A, max. CB, SCCR (UL/CSA)
125/70 A, Class J, max. Fuse, SCCR (UL/CSA)
10/100 kA, Fuse, SCCR (UL/CSA)
10/100 kA, Fuse, SCCR (UL/CSA)
125/125 A, Class J, max. Fuse, SCCR (UL/CSA)
50/32 A, max. CB, SCCR (UL/CSA)
Conventional thermal current
Switching capacity
5 A, 240 V AC, (UL/CSA)
R300, DC operated (UL/CSA)
Magnet system
0.85 - 1.1 V AC x Uc
Contacts
Safety
250 V AC, Between coil and auxiliary contacts, According to EN 61140