DILM32-XTEY20(RAC240) 101448 Y7-101448 EATON ELECTRIC Timer module, 200-240VAC, 1-30s, star-delta
DILM32-XTEY20(RAC240)
101448
Y7-101448
EATON - MOELLER
1 Pcs.
Automation > Timer block
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A timer module, 200-240VAC, 1-30s, star-delta DILM32-XTEY20(RAC240) built by Eaton Moeller automates the transition from star to delta wiring in AC motor starters to reduce starting current surges. Star-delta timing accessories are essential components in industrial motor control schemes for large machinery.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Setting time (EF005922): 1 s
- Number of contacts as normally open contact (EF008256): 2
- Number of contacts as normally closed contact (EF008255): 0
- Number of contacts as change-over contact (EF008257): 0
- Operating principle (EF004139): Electronic
More info
▲General specifications
DIN EN 61812
IEC/EN 60947-4-1
UL Category Control No.: NKCR
CSA Class No.: 3211-03
CSA File No.: 012528
IEC/EN 60947
UL 508
CSA
UL
UL File No.: E29184
VDE 0660
CE
Features & Functions
General
200 ms, Off-delayed
3,000,000 Operations (AC operated)
360 mechanical Operations/h
Ambient conditions, mechanical
6 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Climatic environmental conditions
Damp heat, cyclic, to IEC 60068-2-30
Terminal capacities
2 x (0.75 - 1.5) mm²
1 x (0.75 - 2.5) mm²
2, Terminal screw, Pozidriv screwdriver
Electrical Rating
0.2 A at 60 V, DC-13 L/R - 300 ms (with 1 contact in series)
0.1 A at 220 V, DC-13 L/R - 300 ms (with 1 contact in series)
3 A at AC-15, 220 V 230 V 240 V
1 A at 24 V, DC-13 L/R - 300 ms (with 1 contact in series)
0.1 A at 220 V, DC-13 L/R - 50 ms (with 1 contact in series)
1 A at 24 V, DC-13 L/R - 50 ms (with 1 contact in series)
0.2 A at 110 V, DC-13 L/R - 300 ms (with 1 contact in series)
0.2 A at 110 V, DC-13 L/R - 50 ms (with 1 contact in series)
Short-circuit rating
5 kA, SCCR (UL/CSA)
125 A, max. CB, SCCR (UL/CSA)
10/65 kA, CB, SCCR (UL/CSA)
50/32 A, max. CB, SCCR (UL/CSA)
10/100 kA, Fuse, SCCR (UL/CSA)
10/22 kA, CB, SCCR (UL/CSA)
10/100 kA, Fuse, SCCR (UL/CSA)
50/32 A, max. CB, SCCR (UL/CSA)
Conventional thermal current
Switching capacity
5 A, 240 V AC, (UL/CSA)
B300, AC operated (UL/CSA)
Magnet system
0.7 - 1.2 V DC x Uc
Contacts
Safety
250 V AC, Between auxiliary contacts, According to EN 61140