View larger
DILM32-XTED11-1(RAC130) 105211 Y7-105211 EATON ELECTRIC Timer module, 100-130VAC, 0.05-1s, off-delayed
DILM32-XTED11-1(RAC130)
105211
Y7-105211
EATON - MOELLER
1 Pcs.
Automation > Timer block
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A timer module, 100-130VAC, 0.05-1s, off-delayed DILM32-XTED11-1(RAC130) manufactured by Eaton Moeller is utilized in motor control centers to drop out outputs with a set time lag following power removal. These electronic add-on modules attach directly to contactors for streamlined panel building and sequential switching.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Switching function (EF000189): Time-delay dropped out
- Setting time (EF005922): 0.05 s
- Number of contacts as normally open contact (EF008256): 1
- Number of contacts as normally closed contact (EF008255): 1
- Number of contacts as change-over contact (EF008257): 0
- Operating principle (EF004139): Electronic
More info
▲General specifications
UL 508
CSA File No.: 012528
DIN EN 61812
UL Category Control No.: NKCR
IEC/EN 60947
IEC/EN 60947-4-1
CE
UL
VDE 0660
CSA
CSA Class No.: 3211-03
UL File No.: E29184
Features & Functions
General
200 ms, Off-delayed
3,000,000 Operations (DC operated)
360 mechanical Operations/h
Ambient conditions, mechanical
6 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
1 x (0.75 - 1.5) mm²
2 x (0.75 - 1.5) mm²
2, Terminal screw, Pozidriv screwdriver
Electrical Rating
0.2 A at 60 V, DC-13 L/R - 50 ms (with 1 contact in series)
0.1 A at 220 V, DC-13 L/R - 300 ms (with 1 contact in series)
0.2 A at 60 V, DC-13 L/R - 300 ms (with 1 contact in series)
0.1 A at 220 V, DC-13 L/R - 50 ms (with 1 contact in series)
0.2 A at 110 V, DC-13 L/R - 300 ms (with 1 contact in series)
1 A at 24 V, DC-13 L/R - 50 ms (with 1 contact in series)
3 A at AC-15, 220 V 230 V 240 V
1 A at 24 V, DC-13 L/R - 300 ms (with 1 contact in series)
Short-circuit rating
5 kA, SCCR (UL/CSA)
125 A, max. CB, SCCR (UL/CSA)
50/32 A, max. CB, SCCR (UL/CSA)
125/70 A, Class J, max. Fuse, SCCR (UL/CSA)
10/100 kA, Fuse, SCCR (UL/CSA)
50/32 A, max. CB, SCCR (UL/CSA)
10/100 kA, Fuse, SCCR (UL/CSA)
125/125 A, Class J, max. Fuse, SCCR (UL/CSA)
Switching capacity
5 A, 24 V DC, (UL/CSA)
R300, DC operated (UL/CSA)
Magnet system
0.7 - 1.2 V DC x Uc
Contacts
Safety
250 V AC, Between auxiliary contacts, According to EN 61140