View larger
EMT6-KDB 269471 Y7-269471 EATON ELECTRIC Thermistor overload relay for machine protection, 1N/O+1N/C, 24-240..
EMT6-KDB
269471
Y7-269471
EATON - MOELLER
1 Pcs.
Automation > Temperature monitoring relay
Thermal Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller thermistor overload relay, model EMT6-KDB, protects industrial motors from thermal damage by monitoring winding temperatures via embedded PTC sensors. When excessive heat is detected, the relay trips its internal contacts to safely interrupt the control circuit and prevent motor burnout. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of electric connection (EF003961): Screw connection
- With detachable clamps (EF003340): No
- Voltage type (supply voltage) (EF002991): AC/DC
- Supply voltage AC 50 Hz (EF007532): 24 V
- Supply voltage AC 60 Hz (EF007533): 24 V
- Supply voltage DC (EF007534): 24 V
- Number of measuring circuits (EF003425): 1
- Error registration possible (EF003423): No
- External reset possible (EF003426): Yes
- Temperature measuring range (EF009788): 0 °C
- Resistance measuring range (EF011955): 750 Ohm
- Connection type auxiliary circuit (EF006820): Screw connection
- Number of contacts as normally closed contact (EF008255): 1
- Number of contacts as normally open contact (EF008256): 1
- Number of contacts as change-over contact (EF008257): 0
- Voltage type (operating voltage) (EF005294): AC/DC
More info
▲General specifications
IEC/EN 60947
CSA-C22.2 No. 14
IEC/EN 61000-4-3
CSA
CSA Class No.: 3211-03
IEC/EN 60947-8
IEC/EN 61000-4-2
CE
UL 508
UL File No.: E29184
UL
UL Category Control No.: NKCR
VDE 0660
EN 55011
Features & Functions
Notifications of mains and faults via LED display
Short-circuit in the sensor cable
Test function via separate button
External reset possible
Manual or remote resetting
General
4000 V AC
250 V AC, Between the contacts and power supply, According to EN 61140
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Electro magnetic compatibility
2 kV, Supply cable
According to IEC/EN 61000-4-4
1 V/m at 2.0 - 2.7 GHz (according to IEC EN 61000-4-3)
10 V/m at 80 - 1000 MHz (according to IEC EN 61000-4-3)
According to IEC/EN 61000-4-5, power pulses (Surge), EMC
4 kV, asymmetrical, power pulses (Surge), EMC
Terminal capacities
1 x (0.5 - 2.5) mm², solid
2 x (0.5 - 1.5) mm², flexible with ferrule
20 - 14 AWG, solid or stranded
2 x (0.5 - 1.5) mm², solid
1 x 6 mm, Terminal screw, Standard screwdriver
Electrical rating
3.5 VA at AC
1 A at AC-15, 300 V (NC)
3 A at AC-14, 400 V (NC)
3 A at AC-14, 300 V (NO)
1 A at AC-15, 300 V (NO)
1 A at AC-15, 380 V 400 V 415 V (NO)
3 A at AC-15, 220 V 230 V 240 V
3 A at AC-14, 300 V (NC)
3 A at AC-14, 380 V 400 V 415 V (NO)
3 A at AC-15, 220 V 230 V 240 V (NO)
1 A at AC-15, 380 V 400 V 415 V (NC)
3 A at AC-15, 220 V 230 V 240 V (NC)