View larger
LN2-250-I 112004 Y7-112004 EATON ELECTRIC Switch-disconnector, 3 p, 250A, frame size 2
LN2-250-I
112004
Y7-112004
EATON - MOELLER
1 Pcs.
Connectors > Switch disconnector
Circuit Breakers LZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller Switch-disconnector, 3 p, 250A, frame size 2 (LN2-250-I) is engineered to safely interrupt electrical current flow during maintenance or emergency procedures in industrial environments. These robust switching units protect downstream electrical assets and ensure compliance with electrical safety protocols.
Exact pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Version as main switch (EF006981): Yes
- Version as maintenance-/service switch (EF006986): Yes
- Version as safety switch (EF006985): No
- Version as emergency stop installation (EF006959): Yes
- Version as reversing switch (EF009408): No
- Max. rated operation voltage Ue AC (EF007355): 400 V
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 250 A
- Rated permanent current at AC-21, 400 V (EF009165): 0 A
- Rated operation power at AC-3, 400 V (EF001364): 0 kW
- Rated short-time withstand current lcw (EF007050): 3.5 kA
- Rated operation power at AC-23, 400 V (EF007027): 132 kW
- Switching power at 400 V (EF009166): 0 kW
- Conditioned rated short-circuit current Iq (EF001444): 100 kA
- Number of poles (EF001391): 3
- Motor drive optional (EF007386): Yes
More info
▲General specifications
Product specifications
Version as main switch
Motor drive optional
Version as maintenance-/service switch
Ground mounting
Fixed
Distribution board installation
Intermediate mounting
250 A (415 V AC-1, making and breaking capacity)
250 A (690 V AC-1, making and breaking capacity)
250 A (415 V AC-22/23A, making and breaking capacity)
Max. 10 segments of 16 mm x 0.8 mm at box terminal
Max. 10 segments of 16 mm x 0.8 mm at rear-side connection (punched)
Min. 2 segments of 9 mm x 0.8 mm at box terminal
10000 operations at 400 V AC-1
7500 operations at 690 V AC-1
10000 operations at 415 V AC-1
7500 operations at 400 V AC-3
7500 operations at 415 V AC-3
Interlockable
Voltage release optional
PN2(N2)-160…250: 250 AgGgL
80 kA at 690 V
PN2(N2)-160…250: 250 AgGgL
100 kA at 400/415 V
0.75 mm² - 2.5 mm² (1x)
M8 at rear-side screw connection
Max. 20 mm x 5 mm direct at switch rear-side connection
16 mm² - 185 mm² (1x) at tunnel terminal
4 mm² - 16 mm² (1x) at box terminal
4 mm² - 16 mm² (2x) at box terminal
4 mm² - 16 mm² (1x) direct at switch rear-side connection
25 mm² - 70 mm² (2x) direct at switch rear-side connection
25 mm² - 185 mm² (1x) at box terminal
25 mm² - 185 mm² (1x) at tunnel terminal
25 mm² - 70 mm² (2x) at box terminal