View larger
LN2-200-I 112003 Y7-112003 EATON ELECTRIC Switch-disconnector, 3 p, 200A, frame size 2
LN2-200-I
112003
Y7-112003
EATON - MOELLER
1 Pcs.
Connectors > Switch disconnector
Circuit Breakers LZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller LN2-200-I switch-disconnector serves as a high-performance circuit isolation device designed to handle demanding electrical loads in industrial power distribution architectures. Units of this scale are standard in primary switchboards to safeguard infrastructure and personnel.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Version as main switch (EF006981): Yes
- Version as maintenance-/service switch (EF006986): Yes
- Version as safety switch (EF006985): No
- Version as emergency stop installation (EF006959): Yes
- Version as reversing switch (EF009408): No
- Max. rated operation voltage Ue AC (EF007355): 400 V
- Rated operating voltage (EF001435): 690 V
- Rated permanent current at AC-21, 400 V (EF009165): 0 A
- Rated operation power at AC-3, 400 V (EF001364): 0 kW
- Rated short-time withstand current lcw (EF007050): 3.5 kA
- Rated operation power at AC-23, 400 V (EF007027): 110 kW
- Switching power at 400 V (EF009166): 0 kW
- Conditioned rated short-circuit current Iq (EF001444): 100 kA
- Number of poles (EF001391): 3
- Motor drive optional (EF007386): Yes
- Motor drive integrated (EF006697): No
More info
▲General specifications
Product specifications
Motor drive optional
Version as maintenance-/service switch
Version as emergency stop installation
Distribution board installation
Intermediate mounting
Fixed
Built-in device fixed built-in technique
250 A (690 V AC-1, making and breaking capacity)
250 A (415 V AC-22/23A, making and breaking capacity)
250 A (415 V AC-1, making and breaking capacity)
Max. 10 segments of 16 mm x 0.8 mm at rear-side connection (punched)
Min. 2 segements of 16 mm x 0.8 mm at rear-side connection (punched)
Min. 2 segments of 9 mm x 0.8 mm at box terminal
10000 operations at 415 V AC-1
7500 operations at 415 V AC-3
10000 operations at 400 V AC-1
7500 operations at 400 V AC-3
7500 operations at 690 V AC-1
Voltage release optional
Interlockable
PN2(N2)-160…250: 250 AgGgL
80 kA at 690 V
80 kA at 690 V
100 kA at 400/415 V
0.75 mm² - 1.5 mm² (2x)
Min. 16 mm x 5 mm direct at switch rear-side connection
Max. 20 mm x 5 mm direct at switch rear-side connection
4 mm² - 16 mm² (2x) direct at switch rear-side connection
4 mm² - 16 mm² (1x) at box terminal
4 mm² - 16 mm² (2x) at box terminal
16 mm² - 185 mm² (1x) at tunnel terminal
25 mm² - 70 mm² (2x) direct at switch rear-side connection
25 mm² - 185 mm² (1x) direct at switch rear-side connection
25 mm² - 70 mm² (2x) at box terminal
25 mm² - 185 mm² (1x) at box terminal