View larger
LN2-160-I 112002 Y7-112002 EATON ELECTRIC Switch-disconnector, 3 p, 160A, frame size 2
LN2-160-I
112002
Y7-112002
EATON - MOELLER
1 Pcs.
Connectors > Switch disconnector
Circuit Breakers LZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller LN2-160-I switch-disconnector functions as a reliable mechanical control device used to safely disconnect electrical circuits during maintenance or emergency interventions. These components are typically integrated into industrial distribution boards and machine panels to provide a visible break point and isolate power under load conditions.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Version as main switch (EF006981): Yes
- Version as maintenance-/service switch (EF006986): Yes
- Version as safety switch (EF006985): No
- Version as emergency stop installation (EF006959): Yes
- Version as reversing switch (EF009408): No
- Max. rated operation voltage Ue AC (EF007355): 400 V
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 160 A
- Rated permanent current at AC-21, 400 V (EF009165): 0 A
- Rated operation power at AC-3, 400 V (EF001364): 0 kW
- Rated short-time withstand current lcw (EF007050): 3.5 kA
- Rated operation power at AC-23, 400 V (EF007027): 90 kW
- Switching power at 400 V (EF009166): 0 kW
- Conditioned rated short-circuit current Iq (EF001444): 100 kA
- Number of poles (EF001391): 3
- Motor drive optional (EF007386): Yes
More info
▲General specifications
Product specifications
Motor drive optional
Version as maintenance-/service switch
Version as main switch
Built-in device fixed built-in technique
Intermediate mounting
Distribution board installation
Fixed
250 A (690 V AC-1, making and breaking capacity)
250 A (690 V AC-22/23A, making and breaking capacity)
250 A (415 V AC-1, making and breaking capacity)
Min. 2 segments of 9 mm x 0.8 mm at box terminal
Min. 2 segements of 16 mm x 0.8 mm at rear-side connection (punched)
Max. 10 segments of 16 mm x 0.8 mm at box terminal
10000 operations at 415 V AC-1
7500 operations at 690 V AC-1
10000 operations at 400 V AC-1
7500 operations at 400 V AC-3
7500 operations at 415 V AC-3
Disconnectors/main switches
Voltage release optional
100 kA at 400/415 V
PN2(N2)-160…250: 250 AgGgL
PN2(N2)-160…250: 250 AgGgL
100 kA at 400/415 V
0.75 mm² - 2.5 mm² (1x)
Min. 16 mm x 5 mm direct at switch rear-side connection
Max. 20 mm x 5 mm direct at switch rear-side connection
4 mm² - 16 mm² (2x) direct at switch rear-side connection
16 mm² - 185 mm² (1x) at tunnel terminal
4 mm² - 16 mm² (1x) at box terminal
4 mm² - 16 mm² (2x) at box terminal
25 mm² - 185 mm² (1x) at tunnel terminal
25 mm² - 185 mm² (1x) at box terminal
25 mm² - 70 mm² (2x) at box terminal
25 mm² - 70 mm² (2x) direct at switch rear-side connection