EATON ELECTRIC Switch-disconnector, 3 p, 160A, frame size 1 represented by part LN1-160-I acts as a dependable three-pole load break switch designed for commercial and industrial power distribution boards. These switching units provide safe manual disconnection of electrical supplies during maintenance protocols.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Version as main switch (EF006981): Yes
- Version as maintenance-/service switch (EF006986): Yes
- Version as safety switch (EF006985): No
- Version as emergency stop installation (EF006959): Yes
- Version as reversing switch (EF009408): No
- Max. rated operation voltage Ue AC (EF007355): 400 V
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 160 A
- Rated permanent current at AC-21, 400 V (EF009165): 0 A
- Rated operation power at AC-3, 400 V (EF001364): 0 kW
- Rated short-time withstand current lcw (EF007050): 2 kA
- Rated operation power at AC-23, 400 V (EF007027): 90 kW
- Switching power at 400 V (EF009166): 0 kW
- Conditioned rated short-circuit current Iq (EF001444): 100 kA
- Number of poles (EF001391): 3
- Motor drive optional (EF007386): Yes
More info
▲General specifications
Product specifications
Motor drive optional
Version as emergency stop installation
Version as main switch
Built-in device fixed built-in technique
Fixed
Distribution board installation
Intermediate mounting
160 A (415 V AC-1, making and breaking capacity)
160 A (690 V AC-1, making and breaking capacity)
160 A (415 V AC-22/23A, making and breaking capacity)
Min. 2 segments of 9 mm x 0.8 mm at box terminal
7500 operations at 400 V AC-3
7500 operations at 690 V AC-1
10000 operations at 400 V AC-1
5000 operations at 690 V AC-3
7500 operations at 415 V AC-3
Voltage release optional
Interlockable
PN1(N1)-63…125: 125 AgGgL; PN1(N1)-160: 160 AgGgL
80 kA at 690 V
10 kA at 690 V
PN1(N1)-63…125: 125 AgGgL; PN1(N1)-160: 160 AgGgL
0.75 mm² - 2.5 mm² (1x)
Min. 12 mm x 5 mm direct at switch rear-side connection
M6 at rear-side screw connection
16 mm² (1x) at tunnel terminal
6 mm² - 16 mm² (2x) at box terminal
6 mm² - 16 mm² (2x) direct at switch rear-side connection
10 mm² - 16 mm² (1x) direct at switch rear-side connection
25 mm² - 70 mm² (1x) at box terminal
25 mm² (2x) at box terminal
25 mm² (2x) direct at switch rear-side connection
25 mm² - 95 mm² (1x) at tunnel terminal