View larger
SN3-050-BU8 100640 EATON ELECTRIC Moni stabilized power source
SN3-050-BU8
100640
EATON - MOELLER
1 Pcs.
Automation > PLC system power supply
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Stabilized power source units such as the Eaton Moeller SN3-050-BU8 deliver filtered, regulated electrical output to protect sensitive industrial automation circuits against grid voltage fluctuations. These modules are universally deployed in control cabinets to maintain stable DC or AC rails for sensors, relays, and localized microprocessors. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated operational current for specified heat dissipation: I n
- Heat dissipation per pole, current-dependent: P vid
- Equipment heat dissipation, current-dependent: P vid
- Static heat dissipation, non-current-dependent: P vs
- Heat dissipation capacity: P diss
- IL05012004Z (IL05012004Z) Power supply unit: >>
- Input voltage AC 50 Hz (EF007118): 85 V
- Input voltage AC 60 Hz (EF007119): 85 V
- Input voltage DC (EF007120): 100 V
- Type of voltage (input voltage) (EF003033): AC/DC
- Max. input current AC 50 Hz (EF007360): 2.2 A
- Max. input current AC 60 Hz (EF007361): 2.2 A
- Max. input current DC (EF007362): 1.35 A
- Type of output voltage (EF008222): AC/DC
- Output voltage AC 50 Hz (EF006999): 0 V
- Output voltage AC 60 Hz (EF007000): 0 V
More info
▲Product range | SN3 switched-mode power supply units | ||
Description | Primary pulsed power supply, power reserve from up to 50 % Up to 5 devices can be paralleled to increase power and for redundancy | ||
Phases | Single-phase | ||
Input voltage range | 85 - 264 V AC 100 - 350 V DC | ||
Instructions | At | ||
| General | |||
Standards | EN 61204, 2006/95/EC, 2004/108/EC, EN 50178, EN 60950, UL 60950, UL 508, SELV (EN 60950) | ||
Degree of protection | |||
Enclosures | IP20 | ||
Terminals | IP20 | ||
Protection class | according to EN 61140, Class 1 | ||
Mounting | DIN rail (IEC/EN 60715), snap fixing | ||
Mounting position | Horizontal | ||
Heat dissipation | W | part no. | |
Technical data for design verification | |||
Rated operational current for specified heat dissipation | In | A | 0 |
Heat dissipation per pole, current-dependent | Pvid | W | 0 |
Equipment heat dissipation, current-dependent | Pvid | W | 0 |
Static heat dissipation, non-current-dependent | Pvs | W | 15 |
Heat dissipation capacity | Pdiss | W | 0 |
Operating ambient temperature min. | °C | -25 | |
Operating ambient temperature max. | °C | 70 | |
IEC/EN 61439 design verification | |||
10.2 Strength of materials and parts | |||
10.2.2 Corrosion resistance | Meets the product standard's requirements. | ||
10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. | ||
10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. | ||
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects | Meets the product standard's requirements. | ||
10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. | ||
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.7 Inscriptions | Meets the product standard's requirements. | ||
10.3 Degree of protection of ASSEMBLIES | Meets the product standard's requirements. | ||
10.4 Clearances and creepage distances | Meets the product standard's requirements. | ||
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. | ||
10.8 Connections for external conductors | Is the panel builder's responsibility. | ||
10.9 Insulation properties | |||
10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. | ||
10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. | ||
10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. | ||
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. | ||
10.11 Short-circuit rating | Is the panel builder's responsibility. | ||
10.12 Electromagnetic compatibility | Is the panel builder's responsibility. | ||
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. | ||
| PLC's (EG000024) / PLC system power supply (EC000599) | |||
| Electric engineering, automation, process control engineering / Control / Programmable logic control (SPS) / SPS system power supply ([email protected] [AKE532011]) | |||
Input voltage at AC 50 Hz | V | 85 - 264 | |
Input voltage at AC 60 Hz | V | 85 - 264 | |
Input voltage at DC | V | 100 - 350 | |
Type of voltage (input voltage) | AC/DC | ||
Max. input current AC 50 Hz | A | 2.2 | |
Max. input current AC 60 Hz | A | 2.2 | |
Max. input current DC | A | 1.35 | |
Type of output voltage | DC | ||
Output voltage at AC 50 Hz | V | 0 - 0 | |
Output voltage at AC 60 Hz | V | 0 - 0 | |
Output voltage at DC | V | 0 - 0 | |
Max. output current AC 50 Hz | A | 0 | |
Max. output current AC 60 Hz | A | 0 | |
Max. output current DC | A | 5 | |
Redundancy | Yes | ||
Suitable for safety functions | Yes | ||
Width | mm | 130 | |
Height | mm | 130 | |
Depth | mm | 57 | |