Product range | SN3 switched-mode power supply units | ||
Description | Primary pulsed power supply, power reserve from up to 50 % Up to 5 devices can be paralleled to increase power and for redundancy | ||
Phases | Single-phase | ||
Input voltage range | 85 - 264 V AC 100 - 350 V DC | ||
Instructions | At | ||
| General | |||
Standards | EN 61204, 2006/95/EC, 2004/108/EC, EN 50178, EN 60950, UL 60950, UL 508, SELV (EN 60950) | ||
Degree of protection | |||
Enclosures | IP20 | ||
Terminals | IP20 | ||
Protection class | according to EN 61140, Class 1 | ||
Mounting | DIN rail (IEC/EN 60715), snap fixing | ||
Mounting position | Horizontal | ||
Heat dissipation | W | part no. | |
Technical data for design verification | |||
Rated operational current for specified heat dissipation | In | A | 0 |
Heat dissipation per pole, current-dependent | Pvid | W | 0 |
Equipment heat dissipation, current-dependent | Pvid | W | 0 |
Static heat dissipation, non-current-dependent | Pvs | W | 15 |
Heat dissipation capacity | Pdiss | W | 0 |
Operating ambient temperature min. | °C | -25 | |
Operating ambient temperature max. | °C | 70 | |
IEC/EN 61439 design verification | |||
10.2 Strength of materials and parts | |||
10.2.2 Corrosion resistance | Meets the product standard's requirements. | ||
10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. | ||
10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. | ||
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects | Meets the product standard's requirements. | ||
10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. | ||
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.7 Inscriptions | Meets the product standard's requirements. | ||
10.3 Degree of protection of ASSEMBLIES | Meets the product standard's requirements. | ||
10.4 Clearances and creepage distances | Meets the product standard's requirements. | ||
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. | ||
10.8 Connections for external conductors | Is the panel builder's responsibility. | ||
10.9 Insulation properties | |||
10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. | ||
10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. | ||
10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. | ||
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. | ||
10.11 Short-circuit rating | Is the panel builder's responsibility. | ||
10.12 Electromagnetic compatibility | Is the panel builder's responsibility. | ||
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. | ||
| PLC's (EG000024) / PLC system power supply (EC000599) | |||
| Electric engineering, automation, process control engineering / Control / Programmable logic control (SPS) / SPS system power supply ([email protected] [AKE532011]) | |||
Input voltage at AC 50 Hz | V | 85 - 264 | |
Input voltage at AC 60 Hz | V | 85 - 264 | |
Input voltage at DC | V | 100 - 350 | |
Type of voltage (input voltage) | AC/DC | ||
Max. input current AC 50 Hz | A | 2.2 | |
Max. input current AC 60 Hz | A | 2.2 | |
Max. input current DC | A | 1.35 | |
Type of output voltage | DC | ||
Output voltage at AC 50 Hz | V | 0 - 0 | |
Output voltage at AC 60 Hz | V | 0 - 0 | |
Output voltage at DC | V | 0 - 0 | |
Max. output current AC 50 Hz | A | 0 | |
Max. output current AC 60 Hz | A | 0 | |
Max. output current DC | A | 5 | |
Redundancy | Yes | ||
Suitable for safety functions | Yes | ||
Width | mm | 130 | |
Height | mm | 130 | |
Depth | mm | 57 | |
| Feature Name | Feature Value |
|---|---|
| Input voltage AC 50 Hz (EF007118) | 85 V |
| Input voltage AC 60 Hz (EF007119) | 85 V |
| Input voltage DC (EF007120) | 100 V |
| Type of voltage (input voltage) (EF003033) | AC/DC |
| Max. input current AC 50 Hz (EF007360) | 2.2 A |
| Max. input current AC 60 Hz (EF007361) | 2.2 A |
| Max. input current DC (EF007362) | 1.35 A |
| Type of output voltage (EF008222) | AC/DC |
| Output voltage AC 50 Hz (EF006999) | 0 V |
| Output voltage AC 60 Hz (EF007000) | 0 V |
| Output voltage DC (EF007001) | 0 V |
| Max. output current AC 50 Hz (EF007351) | 0 A |
| Max. output current AC 60 Hz (EF007352) | 0 A |
| Max. output current DC (EF007353) | 5 A |
| Redundancy (EF003156) | Yes |
| Suitable for safety functions (EF001597) | Yes |
| Width (EF000008) | 57 mm |
| Height (EF000040) | 130 mm |
| Depth (EF000049) | 130 mm |