View larger
IN32B3-16W 123644 EATON ELECTRIC Break switch, 3P, 1600A, removable without chassis
IN32B3-16W
123644
EATON - MOELLER
1 Pcs.
Connectors > Switch disconnector
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller IN32B3-16W 123644 EATON ELECTRIC Break switch, 3P, 1600A, removable without chassis units serve as heavy electrical load interrupters for high-capacity industrial power systems. These robust components manage major current distribution safely while offering simplified removal mechanisms for panel maintenance.
Specific pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated current = rated uninterrupted current: I n = I u
- up to 440 V 50/60 Hz: I cm
- t = 1 s: I cw
- Storage: ϑ
- Rated uninterrupted current at 50 °C: I u
- Rated uninterrupted current at 60 °C: I u
- Rated uninterrupted current at 70 °C: I u
- Rated impulse withstand voltage: U imp
- Rated operational voltage: U e
- Use in IT electrical power networks up to U = 440 V: I IT
- Rated insulation voltage: U i
- Switching capacity Rated short-circuit making capacity: I cm
- up to 440 V 50/60 Hz: I cm
- up to 440 V 50/60 Hz: I cm
- Maximum operating frequency: Operations/h
- Version as main switch (EF006981): false
More info
▲Product range | Air circuit-breakers/switch-disconnectors | ||
Product range | Open switch-disconnectors | ||
Current Range | 4000 to 6300 A | ||
Protective function | without protection | ||
Installation type | Withdrawable | ||
Construction size | IN32 | ||
Standard/Approval | IEC | ||
Number of poles | 3 pole | ||
Degree of Protection | IP20, IP55 with protective cover | ||
Rated current = rated uninterrupted current | In= Iu | A | 1600 |
up to 440 V 50/60 Hz | Icm | kA | 55 |
t = 1 s | Icw | kA | 65 |
| Notes Including rear connection main terminals and secondary terminal blocks according to ordered breaker options. | |||
| Note concerning the product Cassette needs to be ordered separately. | |||
| General | |||
Standards | IEC/EN 60947 | ||
Ambient temperature | |||
Storage | ϑ | °C | -40 - +70 |
Operating (open) | °C | -25 - +70 | |
Mounting position | |||
Utilization category | B | ||
Degree of Protection | IP20, IP55 with protective cover | ||
Direction of incoming supply | as required | ||
| Main conducting paths | |||
Rated current = rated uninterrupted current | In= Iu | A | 1600 |
Rated uninterrupted current at 50 °C | Iu | A | 1600 |
Rated uninterrupted current at 60 °C | Iu | A | 1600 |
Rated uninterrupted current at 70 °C | Iu | A | 1600 |
Rated impulse withstand voltage | Uimp | V AC | 8000 |
Rated operational voltage | Ue | V AC | 690 |
Use in IT electrical power networks up to U = 440 V | IIT | kA | 23 |
Overvoltage category/pollution degree | III/3 | ||
Rated insulation voltage | Ui | V | 1000 |
| Switching capacity | |||
Rated short-circuit making capacity | Icm | ||
up to 440 V 50/60 Hz | Icm | kA | 55 |
up to 690 V 50/60 Hz | Icm | kA | 143 |
Operating times | |||
Closing delay via spring release | ms | 35 | |
Break times | ms | 40 | |
Total opening delay via shunt release | ms | 30 | |
Total opening delay via undervoltage release | ms | 35/70 | |
Maximum operating frequency | Ops./h | ||
Maximum operating frequency | Operations/h | 60 | |
Heat dissipation at rated current In | |||
Fixed mounting | W | 150 | |
Withdrawable units (switch with cassette) | W | 330 | |
| Weight | |||
Fixed mounting | |||
3-pole | kg | 58 | |
4-pole | kg | 72 | |
Withdrawable | |||
3-pole | kg | 70 | |
4-pole | kg | 88 | |
Cassette | |||
3 pole | kg | 34 | |
4 pole | kg | 38 | |
| Terminal capacities | |||
Copper bar | |||
Fixed mounting | |||
Black | mm | 2 x 5 x 100 | |
Withdrawable units | |||
Black | mm | 2 x 5 x 100 | |
| Permissible continuous current for circuit‐breakers operating in switchboards at various internal ambient temperatures. The switchboard’s internal ambient temperature should be estimated using the calculation methods of IEC regulation. | |||