EATON - MOELLER SWD4-4LR4P-R SWD4-4LR4P-R 183199 Y7-183199 EATON ELECTRIC MB-Power-cable IP67 for connecting the Multiblock, 4 m , prefab.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SWD4-4LR4P-R 183199 Y7-183199 EATON ELECTRIC MB-Power-cable IP67 for connecting the Multiblock, 4 m , prefab..

SWD4-4LR4P-R

183199

Y7-183199

EATON - MOELLER

1 Pcs.

MB-Power-cable IP67 for connecting the Multiblock, 4 m , prefabricated with 7/8" plug SWD4-4LR4P-R Eaton SWD4 MB-Power-cable, IP67, 4 m, 4 pole, Prefabricated on one side with 7/8" right-angle socket 4 pole MB-Power-cable IP67 degree of protection for connecting the Multiblock I/O module, bare cables, 4 m long, Prefabricated with 7/8z angled plug

Cables > Data and communication cable
Smartwire Darwin

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton SWD4 Accessory MB-Power-cable
Catalog Number
183199
Model Code
SWD4-4LR4P-R
EAN
4015081781324
Product Length/Depth
307.692 mm
Product Height
51.282 mm
Product Width
307.692 mm
Product Weight
0.614 kg
Certifications
CSA
UL
Catalog Notes
Condensation: permissible

Features & Functions

Features
Longitudinal water blocking cable
Oil resistant (acc. EN 60811-404)
Oil resistant (acc. IEC 60811-404)
Radial water blocking cable
Fitted with:
7/8" right-angle socket on one side
Functions
For directly connecting the power supply to EU6E.., EU8E.. IP67 SmartWire-DT modules

General

Cable length
4 m
Number of Poles
Four-pole
Outer diameter - approximate
11 mm
Outer sheath material
Polyvinyl chloride (PVC)
Permitted bending radius, moving application with forced guidance - min
0 mm
Product category
SmartWire-DT accessories
Suitable as
Signaling cable

Climatic environmental conditions

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
70 °C

Safety

Flame retardant
In accordance with EN 60332-1-2

Design verification

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 183199 Cable (EC003249)
Feature Name Feature Value
Cable type (EF000081) Other
Duplex (EF023003) No
Conductor material (EF001622) Other
Conductor surface (EF010804) Bare
Diameter conductor (EF001621) 1.5 mm
Nominal cross section conductor (EF000060) 0.5 mm²
AWG size (EF011789) 20
Conductor category (EF001632) Class 2 = stranded
Number of cores (EF001792) 4
Number of stranding elements (EF001688) 26
Stranding element (EF001617) Pairs
Material core insulation (EF000061) Other
Specification core insulation (EF011805) Other
Core identification according to HD 308 S2 (EF013766) No
Core identification (EF000067) Colour
Screen over stranding element (EF001623) Foil
Stranding (EF003802) Bundle
Screen over stranding (EF001624) None
Longitudinal water blocking cable (EF011011) Yes
Radial water blocking cable (EF011012) Yes
Suitable for underground installation (EF003689) No
Approved type of underground installation (EF015176) Other
Protective sheath (EF001691) Other
Material outer sheath (EF001625) Polyvinyl chloride (PVC)
Specification material outer sheath (EF011806) Other
Colour outer sheath (EF001618) Black
Number of sheath layers (EF016997) 0
Armouring/reinforcement (EF001683) None
Material armouring (EF013440) Other
Cable geometry (EF013532) Round
Flame retardant according to IEC 60332-1-2 (EF016492) No
Flame retardant according to IEC 60332-3-21 (Cat A F/R) (EF016493) No
Flame retardant according to IEC 60332-3-22 (Cat A) (EF016494) No
Flame retardant according to IEC 60332-3-23 (Cat B) (EF016495) No
Flame retardant according to IEC 60332-3-24 (Cat C) (EF016496) No
Flame retardant according to IEC 60332-3-25 (Cat D) (EF016497) No
Low smoke according to EN IEC 61034-2 (EF003799) No
Halogen free according to EN IEC 60754-1 (EF016498) No
Halogen free according to EN IEC 60754-2 (EF003792) No
Halogen free according to EN IEC 60754-3 (EF016500) No
Reaction-to-fire according to EN 13501-6: Class (EF011577) None
Reaction-to-fire according to EN 13501-6: Smoke production (EF011578) None
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles (EF011579) None
Reaction-to-fire according to EN 13501-6: Acidity (EF011580) None
Circuit integrity according to IEC 60331-23 (EF016619) No
Oil resistant according to EN IEC 60811-404 (EF009770) Yes
Outer diameter approx. (EF003921) 11 mm
Min. permitted bending radius, moving application with forced guidance (EF011801) 0 mm
Min. permitted bending radius, moving application/free movement (EF011802) 0 mm
Min. permitted bending radius, stationary application/permanent installation (EF011803) 64 mm
Permitted cable outer temperature during assembling/handling (EF001685) -25 °C
Permitted cable outer temperature after assembling without vibration (EF001686) -25 °C
Category (EF001619) Other
NVP value (EF008387) 66.5 %
Certified for shipboard application (EF013772) No
Suitable as telephone cable (EF013768) No
Suitable as computer data cable (EF013769) No
Suitable as signalling cable (EF013770) Yes
Suitable for use as security alarm cable (EF017089) No
Drain wire (EF001029) No
With rip cord (EF017088) No
Cable width approx. (EF003796) 5.6 mm
Cable height approx. (EF003797) 51.282 mm
Characteristic impedance (EF001628) 100 Ohm
Nominal voltage U (EF001615) 24 V
With rodent protection (EF007960) No
Compatible with Grade2TV according to XP-C 90-483 (EFFR0001) No
Compatible with Grade3TV according to XP-C 90-483 (EFFR0002) No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.