EATON - MOELLER SPB-D-125 SPB-D-125 248145 EATON ELECTRIC Lead-through terminal for B-type arresters, 125A, 500V AC/DC, overvoltage ca.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SPB-D-125 248145 EATON ELECTRIC Lead-through terminal for B-type arresters, 125A, 500V AC/DC, overvoltage ca..

SPB-D-125

248145

EATON - MOELLER

1 Pcs.

Lead-through terminal for B-type arresters, 125A, 500V AC/DC, overvoltage category III Lead-through terminal for B-type arresters, rated operational current 125A, rated operating voltage 500V AC/DC, overvoltage category III, standard front dimension 45 mm, mounting width 1 SU (17.5mm), top-hat rail mounting, terminal cross-section 0.5-35 mm² solid / 0.5-25 mm² flexible, type conform to IIEC 61643-1: 1998-02, EDIN VDE 0675 part6: 1989-11, IEC 61024-1: 1990-03, IEC 60947-7-1: 1989-10, DIN VDE 0110-1: 1997-04

Automation > Auxiliary device for distribution board devices
Modular Switchgear – Industrial

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Lead-through terminal for B-type arresters, 125A, 500V AC/DC, overvoltage category III
Lead-through terminal for B-type arresters, rated operational current 125A, rated operating voltage 500V AC/DC, overvoltage category III, standard front dimension 45 mm, mounting width 1 SU (17.5mm), top-hat rail mounting, terminal cross-section 0.5-35 mm² solid / 0.5-25 mm² flexible, type conform to IIEC 61643-1: 1998-02, EDIN VDE 0675 part6: 1989-11, IEC 61024-1: 1990-03, IEC 60947-7-1: 1989-10, DIN VDE 0110-1: 1997-04
[

Design verification as per IEC/EN 61439

Rated operational current for specified heat dissipation [In]
0 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-40 °C
Operating ambient temperature max.
+85 °C
0
,

Technical data ETIM 7.0

Devices for distribution board-/surface mounting (EG000062) / Auxiliary device for distribution board devices (EC001286)
Electric engineering, automation, process control engineering / Electrical installation, device / Breaker switch component / Auxiliary contact unit for distribution board ([email protected] [AKE327013])
Device fitting
Other
Additional equipment
Other
Attached at delivery
No
Assembly width (TE)
1
Number of contacts as normally open contact
Number of contacts as normally closed contact
Number of contacts as change-over contact
Number of fault-signal switches
0
Rated switch current
125 A
Rated voltage
500 V
Voltage type for actuating
AC/DC
With auto test for earth leakage function
No
Suitable for max. number of poles main contact unit (total)
1
Suitable for max. current main contact unit
12 A
]

ETIM for 248145 Modular devices for distribution board/surface mounting (EC001286)
Feature Name Feature Value
Device fitting (EF007826) Other
Width in number of modular spacings (EF002950) 1
Number of fault-signal switches (EF007613) 0
Rated switch current (EF006706) 125 A
Rated voltage (EF000228) 500 V
Voltage type (EF000187) AC/DC
With auto test for earth leakage function (EF008727) No
Suitable for max. number of poles main contact unit (total) (EF008729) 1
Suitable for max. current main contact unit (EF008730) 12 A

Product Datasheet