EATON - MOELLER ES4P-BOX-221-DMXD1 ES4P-BOX-221-DMXD1 115126 Y7-115126 EATON ELECTRIC Starter kit with ES4P-221-DMXD1, ESP-SOFT, easy800-USB-CAB View larger
Images are for illustrative purposes only. Please refer to data sheet for details

ES4P-BOX-221-DMXD1 115126 Y7-115126 EATON ELECTRIC Starter kit with ES4P-221-DMXD1, ESP-SOFT, easy800-USB-CAB

ES4P-BOX-221-DMXD1

115126

Y7-115126

EATON - MOELLER

1 Pcs.

Starter kit with ES4P-221-DMXD1, ESP-SOFT, easy800-USB-CAB ES4P-BOX-221-DMXD1 Eaton Moeller® series ES4P Starter kit with ES4P-221-DMXD1, ESP-SOFT, easy800-USB-CAB Starter kit for the easy access to the safety control technology. The starter kit includes a safety-related control relay ES4P-221-DMXD1, the programming cable easy800-USB-CAB for connecting the safety relay to the USB interface of the computer, the programming software easySoft-Safety on CD as well as the documentation and manual as pdf. thus 14 safe digital inputs, 1 safe as well as redundant relay outputs 6A, 4 transistor safety outputs 0.A and 5 test signal outputs are available.

Automation > PLC device set
EASY programmable relays and MFD displays

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Moeller® series ES4P Starter kit
Catalog Number
115126
Model Code
ES4P-BOX-221-DMXD1
EAN
4015081145249
Product Length/Depth
200 mm
Product Height
115 mm
Product Width
255 mm
Product Weight
0.511 kg
Compliances
CE
Catalog Notes
Current consumption at 24 V DC (ES4P-221-DMXD1)

Features & Functions

Features
Expandable
Fitted with:
Timer
Relay output
Basic device
Connection cable
Control unit
Documentation
Software preinstalled
Programming software
Memory unit

General

Mounting method
Wall mounting/direct mounting
Rail mounting possible
Type
Starter kit easySafety

Input/Output

Number of inputs (analog)
0
Number of outputs (digital)
5

Design verification

10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 115126 PLC's (EC002581)
Feature Name Feature Value
Contains function building blocks (EF007145) No
Contains basic device (EF007147) Yes
Contains module rack (EF007138) No
Contains power supply (EF007157) No
Contains analogue input module (EF007137) No
Contains analogue output module (EF007136) No
Contains digital input module (EF007142) No
Contains digital output module (EF007141) No
Contains function module (EF007146) No
Contains technology module (EF007159) No
Contains communication module (EF007149) No
Contains memory unit (EF007156) Yes
Contains simulation module (EF007153) No
Contains connection cable (EF007160) Yes
Contains control unit (EF007139) Yes
Contains monitor (EF007150) No
Contains programming software (EF007152) Yes
Contains engineering software (EF007144) No
Contains visualization (EF007161) No
Contains libraries (EF007140) No
Contains documentation (EF007143) Yes
Contains other components (EF007162) No
Software preinstalled (EF007484) Yes

Product Datasheet