Eaton Moeller standard auxiliary contact NHI-E-11-PKZ0 (082882) mounts onto motor protective circuit breakers to provide remote status feedback and interlocking signals. Auxiliary contacts are widely deployed in industrial control enclosures to relay breaker position data to PLCs and indicator lights.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Name: Eaton Moeller® series NHI Accessory Standard auxiliary contact
- Catalog Number: 082882
- Model Code: NHI-E-11-PKZ0
- EAN: 4015080828822
- Product Length/Depth: 12 mm
- Product Height: 35 mm
- Product Width: 45 mm
- Product Weight: 0.016 kg
- Lifespan, electrical: 100,000 Operations
- Lifespan, mechanical: 100,000 Operations
- Model: Top mounting
- Mounting method: Front fastening
- Overvoltage category: III
- Pollution degree: 3
- Product category: Accessories
- Rated impulse withstand voltage (Uimp): 4000 V AC
More info
▲General specifications
| Product Name | Eaton Moeller® series NHI Accessory Standard auxiliary contact |
| Catalog Number | 082882 |
| Model Code | NHI-E-11-PKZ0 |
| EAN | 4015080828822 |
| Product Length/Depth | 12 mm |
| Product Height | 35 mm |
| Product Width | 45 mm |
| Product Weight | 0.016 kg |
| Certifications | CE UL Category Control No.: NLRV CSA CSA-C22.2 No. 14 UL File No.: E36332 CSA File No.: 165628 IEC/EN 60947-4-1 UL 508 CSA Class No.: 3211-05 UL |
| Catalog Notes | Can be fitted to the front. Terminal designation differs to that of an auxiliary contact that can be fitted to the side |
General
| Lifespan, electrical | 100,000 Operations |
| Lifespan, mechanical | 100,000 Operations |
| Model | Top mounting |
| Mounting method | Front fastening |
| Overvoltage category | III |
| Pollution degree | 3 |
| Product category | Accessories |
| Rated impulse withstand voltage (Uimp) | 4000 V AC |
| Used with | Motor protective circuit-breaker |
Climatic environmental conditions
| Ambient operating temperature - min | -25 °C |
| Ambient operating temperature - max | 55 °C |
Terminal capacities
| Terminal capacity (solid/flexible with ferrule) | 0.75 - 1.5 mm² |
| Terminal capacity (solid/stranded AWG) | 18 - 16, Screw terminals |
Electrical rating
| Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V | 1 A |
| Rated operational current (Ie) at DC-13, 24 V | 2 A |
| Rated operational voltage (Ue) at AC - max | 440 V |
| Rated operational voltage (Ue) at DC - max | 250 V |
| Safe isolation | 440 V, Between auxiliary contacts and main contacts, According to EN 61140 |
| Short-circuit protection rating without welding | 10 A gG/gL, Fuse, Auxiliary contacts |
Contacts
| Number of contacts (change-over contacts) | 0 |
| Number of contacts (normally closed contacts) | 1 |
| Number of contacts (normally open contacts) | 1 |
Design verification
| Equipment heat dissipation, current-dependent Pvid | 0 W |
| Heat dissipation capacity Pdiss | 0 W |
| Heat dissipation per pole, current-dependent Pvid | 0.01 W |
| Rated operational current for specified heat dissipation (In) | 1 A |
| Static heat dissipation, non-current-dependent Pvs | 0 W |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |