EATON - MOELLER SPRT12-264/4-AX SPRT12-264/4-AX 183184 EATON ELECTRIC Combined arrester, transient voltage surge suppression T1&T2 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SPRT12-264/4-AX 183184 EATON ELECTRIC Combined arrester, transient voltage surge suppression T1&T2

SPRT12-264/4-AX

183184

EATON - MOELLER

1 Pcs.

Combined arrester, transient voltage surge suppression T1&T2; Multi-pole combined arrester, type 1 as specified in EN 61643-11, spark-gap-based, consisting of base and plug-in protection modules. Maximum system availability ensured by means of RADAX Flow follow current limiting. Allows for end-device protection. For protecting low-voltage consumer installations from overvoltages, even in the event of direct lightning strikes. Application according to lightning protection zone approach at interfaces 0A– 2.

Automation > Combined arrester for power supply systems
Modular Switchgear – Industrial

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Eaton Moeller SPRT12-264/4-AX combined arrester provides heavy-duty transient voltage surge suppression across complex industrial power distribution networks. These multi-pole units are installed to divert high-energy electrical surges away from sensitive automation electronics. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • System configuration DC (EF009926): No
  • System configuration IT (EF009927): Yes
  • System configuration TN (EF009928): Yes
  • System configuration TN-C (EF009929): No
  • System configuration TN-C-S (EF009933): Yes
  • System configuration TN-S (EF009930): Yes
  • System configuration TT (EF009931): Yes
  • System configuration other (EF009932): Yes
  • Number of poles (EF001391): 4
  • Lightning impulse current (10/350 µs) (EF000421): 100 kA
  • Max. continuous voltage AC (EF004198): 264 V
  • Max. continuous voltage DC (EF004777): 0 V
  • Nominal voltage AC (EF004220): 230 V
  • Nominal voltage DC (EF004221): 0 V
  • Max. PV-voltage (EF008795): 0 V
  • Voltage protection level (EF003525): 1.5 kV

More info

▲
Combined arrester, transient voltage surge suppression T1&T2;
Multi-pole combined arrester, type 1 as specified in EN 61643-11, spark-gap-based, consisting of base and plug-in protection modules. Maximum system availability ensured by means of RADAX Flow follow current limiting. Allows for end-device protection. For protecting low-voltage consumer installations from overvoltages, even in the event of direct lightning strikes. Application according to lightning protection zone approach at interfaces 0A– 2.
[

Delivery program

Products
Surge arresters
Application field
Residential buildings
Utility buildings
Open areas
,

Technical data ETIM 6.0

Earthing, lightning and surge protection (EG000021) / Combined arrester for power supply systems (EC001457)
Electric engineering, automation, process control engineering / Protection installation, device (electric) / Surge protection device (inner lightning protection) / Combined lightning current/surge arrester f. power supply s. ([email protected] [ACN284008])
System configuration DC
No
System configuration IT
Yes
System configuration TN
Yes
System configuration TN-C
No
System configuration TN-C-S
Yes
System configuration TN-S
Yes
System configuration TT
Yes
System configuration other
Yes
Number of poles
4
Lightning impulse current (10/350)
100 kA
Max. continuous voltage AC
264 V
Max. continuous voltage DC
0 V
Nominal voltage AC
230 V
Nominal voltage DC
0 V
Max. PV-voltage
0 V
Voltage protection level
1.5 kV
Voltage protection level L-N
1.5 kV
Voltage protection level N-PE
1.5 kV
Voltage protection level (DC+ - DC-)
0 kV
Voltage protection level (DC+/DC- - PE)
0 kV
Follow current extinguishing capability
50 kA
Specific energy (W/R)
2500 kJ/Ohm
Max. conductor cross section solid (solid, stranded)
50 mm²
Max. conductor cross section flexible (fine-strand)
35 mm²
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
8 modular spacing
Remote signalling
Yes
Signalling at the device
Optic
Test class
Type 1 + 2
Exhausting
No
Integrated backup fuse
No
Energy-coordinated protection effect with regard to the terminal equipment
Yes
]

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.