EATON - MOELLER SPRT12-264/3+NPE-AX SPRT12-264/3+NPE-AX 183185 EATON ELECTRIC Protection surge T1+T2+T3, 3+N-pole+AX View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SPRT12-264/3+NPE-AX 183185 EATON ELECTRIC Protection surge T1+T2+T3, 3+N-pole+AX

SPRT12-264/3+NPE-AX

183185

EATON - MOELLER

1 Pcs.

Protection surge T1+T2+T3, 3+N-pole+AX Multi-pole combined arrester, type 1 as specified in EN 61643-11, spark-gap-based, consisting of base and plug-in protection modules. Maximum system availability ensured by means of RADAX Flow follow current limiting. Allows for end-device protection. For protecting low-voltage consumer installations from overvoltages, even in the event of direct lightning strikes. Application according to lightning protection zone approach at interfaces 0A– 2.

Automation > Combined arrester for power supply systems
Modular Switchgear – Industrial

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info


ETIM for 183185 Earthing, lightning and surge protection (EC001457)
Feature Name Feature Value
System configuration DC (EF009926) No
System configuration IT (EF009927) Yes
System configuration TN (EF009928) Yes
System configuration TN-C (EF009929) Yes
System configuration TN-C-S (EF009933) Yes
System configuration TN-S (EF009930) Yes
System configuration TT (EF009931) Yes
System configuration other (EF009932) Yes
Number of poles (EF001391) 4
Lightning impulse current (10/350 µs) (EF000421) 100 kA
Max. continuous voltage AC (EF004198) 264 V
Max. continuous voltage DC (EF004777) 0 V
Nominal voltage AC (EF004220) 230 V
Nominal voltage DC (EF004221) 0 V
Max. PV-voltage (EF008795) 0 V
Voltage protection level (EF003525) 1.5 kV
Voltage protection level L-N (EF004236) 1.5 kV
Voltage protection level N-PE (EF008796) 1.5 kV
Voltage protection level (DC+ - DC-) (EF009643) 0 kV
Voltage protection level (DC+/DC- - PE) (EF009644) 0 kV
Follow current extinguishing capability (EF004193) 50 kA
Specific energy (W/R) (EF009797) 2500 kJ/Ohm
Mounting method (EF000003) DIN rail (top hat rail) 35 mm
Construction size (EF002566) 8 modular spacing
Max. conductor cross section solid (solid, stranded) (EF008827) 50 mm²
Max. conductor cross section flexible (fine-strand) (EF008828) 35 mm²
Remote signalling (EF004192) Yes
Signalling at the device (EF004241) Optic
Test class (EF004228) Type 1 + 2
Integrated backup fuse (EF008797) No
Energy-coordinated protection effect with regard to the terminal equipment (EF009798) Yes
Voltage switching spark gap technology (EF016003) No
Overcurrent protected voltage tapping (EF016004) No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.