EATON - MOELLER SPRT12-264/3-AX SPRT12-264/3-AX 183183 EATON ELECTRIC Combined arrester, transient voltage surge suppression T1&T2 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SPRT12-264/3-AX 183183 EATON ELECTRIC Combined arrester, transient voltage surge suppression T1&T2

SPRT12-264/3-AX

183183

EATON - MOELLER

1 Pcs.

Combined arrester, transient voltage surge suppression T1&T2; Multi-pole combined arrester, type 1 as specified in EN 61643-11, spark-gap-based, consisting of base and plug-in protection modules. Maximum system availability ensured by means of RADAX Flow follow current limiting. Allows for end-device protection. For protecting low-voltage consumer installations from overvoltages, even in the event of direct lightning strikes. Application according to lightning protection zone approach at interfaces 0A– 2.

Automation > Combined arrester for power supply systems
Modular Switchgear – Industrial

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Combined arrester, transient voltage surge suppression T1&T2;
Multi-pole combined arrester, type 1 as specified in EN 61643-11, spark-gap-based, consisting of base and plug-in protection modules. Maximum system availability ensured by means of RADAX Flow follow current limiting. Allows for end-device protection. For protecting low-voltage consumer installations from overvoltages, even in the event of direct lightning strikes. Application according to lightning protection zone approach at interfaces 0A– 2.
[

Delivery program

Products
Surge arresters
Application field
Residential buildings
Utility buildings
Open areas
,

Technical data ETIM 6.0

Earthing, lightning and surge protection (EG000021) / Combined arrester for power supply systems (EC001457)
Electric engineering, automation, process control engineering / Protection installation, device (electric) / Surge protection device (inner lightning protection) / Combined lightning current/surge arrester f. power supply s. ([email protected] [ACN284008])
System configuration DC
No
System configuration IT
Yes
System configuration TN
Yes
System configuration TN-C
Yes
System configuration TN-C-S
Yes
System configuration TN-S
No
System configuration TT
No
System configuration other
Yes
Number of poles
3
Lightning impulse current (10/350)
75 kA
Max. continuous voltage AC
264 V
Max. continuous voltage DC
0 V
Nominal voltage AC
230 V
Nominal voltage DC
0 V
Max. PV-voltage
0 V
Voltage protection level
1.5 kV
Voltage protection level L-N
1.5 kV
Voltage protection level N-PE
0 kV
Voltage protection level (DC+ - DC-)
0 kV
Voltage protection level (DC+/DC- - PE)
0 kV
Follow current extinguishing capability
50 kA
Specific energy (W/R)
1400 kJ/Ohm
Max. conductor cross section solid (solid, stranded)
50 mm²
Max. conductor cross section flexible (fine-strand)
35 mm²
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
6 modular spacing
Remote signalling
Yes
Signalling at the device
Optic
Test class
Type 1 + 2
Exhausting
No
Integrated backup fuse
No
Energy-coordinated protection effect with regard to the terminal equipment
Yes
]

ETIM for 183183 Earthing, lightning and surge protection (EC001457)
Feature Name Feature Value
System configuration DC (EF009926) No
System configuration IT (EF009927) Yes
System configuration TN (EF009928) Yes
System configuration TN-C (EF009929) Yes
System configuration TN-C-S (EF009933) Yes
System configuration TN-S (EF009930) No
System configuration TT (EF009931) No
System configuration other (EF009932) Yes
Number of poles (EF001391) 3
Lightning impulse current (10/350 µs) (EF000421) 75 kA
Max. continuous voltage AC (EF004198) 264 V
Max. continuous voltage DC (EF004777) 0 V
Nominal voltage AC (EF004220) 230 V
Nominal voltage DC (EF004221) 0 V
Max. PV-voltage (EF008795) 0 V
Voltage protection level (EF003525) 1.5 kV
Voltage protection level L-N (EF004236) 1.5 kV
Voltage protection level N-PE (EF008796) 0 kV
Voltage protection level (DC+ - DC-) (EF009643) 0 kV
Voltage protection level (DC+/DC- - PE) (EF009644) 0 kV
Follow current extinguishing capability (EF004193) 50 kA
Mounting method (EF000003) DIN rail (top hat rail) 35 mm
Construction size (EF002566) 6 modular spacing
Max. conductor cross section solid (solid, stranded) (EF008827) 50 mm²
Max. conductor cross section flexible (fine-strand) (EF008828) 35 mm²
Remote signalling (EF004192) Yes
Signalling at the device (EF004241) Optic
Test class (EF004228) Type 1 + 2
Integrated backup fuse (EF008797) No
Energy-coordinated protection effect with regard to the terminal equipment (EF009798) Yes
Voltage switching spark gap technology (EF016003) No
Overcurrent protected voltage tapping (EF016004) No

Product Datasheet