EATON - MOELLER SPPVRT2-10-2+PE-AX SPPVRT2-10-2+PE-AX EP-501967 Y7-501967 EATON ELECTRIC PV-SPD, 1000V, Class 2 with AUX contact View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SPPVRT2-10-2+PE-AX EP-501967 Y7-501967 EATON ELECTRIC PV-SPD, 1000V, Class 2 with AUX contact

SPPVRT2-10-2+PE-AX

EP-501967

Y7-501967

EATON - MOELLER

1 Pcs.

PV-SPD, 1000V, Class 2 with AUX contact PV-Surge protection device, 1000V, class 2 tested with AUX contact SPD for the protection of PV installations on the DC side, to be used in accordance with IEC/EN 60364-5-53

Automation > Surge protection device for power supply systems
Modular Switchgear – Industrial

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton xPole SPPVR surge protection device
Catalog Number
EP-501967
Model Code
SPPVRT2-10-2+PE-AX
EAN
9010653062882
Product Length/Depth
104 mm
Product Height
60 mm
Product Width
54 mm
Product Weight
0.296 kg
Certifications
CE

Product specifications

Features
Category type 2
Fitted with:
Remote signaling contact
Frame
3 modular spacing
Degree of protection
IP20
Mounting method
DIN rail (top hat rail) 35 mm
Signalling at the device
Optic
System configuration type
DC
Conductor cross section (flexible, fine-strand) - max
25 mm²
Conductor cross section (solid, solid-strand) - max
35 mm²
Continuous voltage at DC - max
1000 V
Discharge surge current (8/20) - max
40 kA
Nominal discharge surge current (8/20)
20 kA
Nominal voltage at DC
1000 V
Number of conductors without earthing
2
PV-voltage - max
1000 V
Short-circuit breaking capacity (ISCCR)
9 kA
Voltage protection level
3.9 KV

ETIM for EP-501967 Earthing, lightning and surge protection (EC000941)
Feature Name Feature Value
System configuration DC (EF009926) Yes
System configuration IT (EF009927) No
System configuration TN (EF009928) No
System configuration TN-C (EF009929) No
System configuration TN-C-S (EF009933) No
System configuration TN-S (EF009930) No
System configuration TT (EF009931) No
System configuration other (EF009932) No
Number of conductors (without earthing) (EF001148) 2
Nominal discharge surge current (8/20) (EF004214) 20 kA
Max. discharge surge current (8/20) (EF012274) 40 kA
Nominal voltage DC (EF004221) 1000 V
Max. continuous voltage DC (EF004777) 1000 V
Max. PV-voltage (EF008795) 1000 V
Voltage protection level (EF003525) 3.9 kV
Short-circuit breaking capacity (Isccr) (EF012627) 9 kA
Integrated short-circuit protection (EF016000) No
Integrated backup fuse (EF008797) No
Leakage-current free (EF016002) No
Mounting method (EF000003) DIN rail (top hat rail) 35 mm
Construction size (EF002566) 3 modular spacing
Max. conductor cross section solid (solid, stranded) (EF008827) 35 mm²
Max. conductor cross section flexible (fine-strand) (EF008828) 25 mm²
With remote signalling contact (EF000422) Yes
Signalling at the device (EF004241) Optic
Category type 2 (EF004230) Yes
Degree of protection (IP) (EF005474) IP20

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.