EATON - MOELLER NZM-XPC-KIT NZM-XPC-KIT 265631 0004359056 EATON ELECTRIC Software kit, for NZM and DMI View larger
Images are for illustrative purposes only. Please refer to data sheet for details

NZM-XPC-KIT 265631 0004359056 EATON ELECTRIC Software kit, for NZM and DMI

NZM-XPC-KIT

265631

0004359056

EATON - MOELLER

1 Pcs.

Software kit, for NZM and DMI Optional accessories for circuit-breaker series NZM offers a comprehensive portfolio of application possibilities for worldwide use. Modular functional groups make mounting flexible and simple. Note: PC software for direct connection to all new NZM circuit-breakers with electronic releases (IEC and UL/CSA devices) or on the DMI module, including connection cable for NZM. Online display protection parameters and characteristic-curve representations, export possibility to Moeller CurveSelect characteristic-curves program. Warning and release messages: Reading of diagnostic memory also in volt-free status . load currents, display and trend indication. Recording and export options to Excel for load currents and diagnostic messages. Configuration of the DMI motor starter, remote operator configuration of DMI inputs and outputs., display indicators. Only for use in combination with circuit-breakers having electronic releases. Order connecting cable to DMI separately: EASY-USB-CAB. Usable for NZM2(-4), NZM3(-4), NZM4(-4)

Automation > Fieldbus, decentr. periphery - communication module
Circuit Breakers NZM Accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Eaton Moeller NZM-XPC-KIT is a software kit, for NZM and DMI designed for configuring, programming, and managing industrial control devices within automated systems. Software packages of this type provide engineers with the necessary interface tools to adjust parameters, monitor diagnostic data, and update firmware across connected hardware components. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Supply voltage AC 50 Hz (EF007532): 0 V
  • Supply voltage AC 60 Hz (EF007533): 0 V
  • Supply voltage DC (EF007534): 0 V
  • Voltage type (supply voltage) (EF002991): DC
  • Supporting protocol for EtherCAT (EF017564): No
  • Supporting protocol for TCP/IP (EF003050): No
  • Supporting protocol for PROFIBUS (EF003052): No
  • Supporting protocol for CAN (EF003053): No
  • Supporting protocol for INTERBUS (EF003054): No
  • Supporting protocol for ASI (EF003051): No
  • Supporting protocol for KNX (EF003055): No
  • Supporting protocol for Modbus (EF003057): No
  • Supporting protocol for Data-Highway (EF003058): No
  • Supporting protocol for DeviceNet (EF003059): No
  • Supporting protocol for SUCONET (EF003060): No
  • Supporting protocol for LON (EF003017): No

More info

General specifications

Product Name
Eaton Moeller series NZM electronic accessory
Catalog Number
265631
Model Code
NZM-XPC-KIT
EAN
4015082656317
Product Length/Depth
165 mm
Product Height
70 mm
Product Width
140 mm
Product Weight
0.475 kg
Compliances
RoHS conform

Product specifications

Used with
NZM4(-4)
NZM3(-4)
Diagnostics, communication
NZM2(-4)
Special features
Diagnostics and configuration software for NZM and DMI (local)PC software for direct connection to all NZM circuit-breakers with electronic releases (IEC and UL/CSA devices), including the connection cable required in order to connect to an NZM device.• Protection parameter: Online display and curve display, export option to curve characteristics program “Moeller CurveSelect”.• Warning and release messages: Reading of diagnostic memory also in volt-free state.• Load currents: Display and trend indication.• Recording and export options to Excel for load currents and diagnostic messages.• Configuration of the DMI: Motor starter, remote operator, assignment of the DMI inputs and outputs and displays.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Fitted with:
Potential separation
Explosion safety category for dust
Other
Explosion safety category for gas
None
Mounting method
Front build in possible
Voltage type
DC
Safety performance level (EN ISO 13849-1)
None
SIL (IEC 61508)
None
Degree of protection
IP20
System accessory
No
Supply voltage at AC, 50 Hz - max
0 V
Supply voltage at AC, 50 Hz - min
0 V
Supply voltage at AC, 60 Hz - max
0 V
Supply voltage at AC, 60 Hz - min
0 V
Supply voltage at DC - max
0 V
Supply voltage at DC - min
0 V

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.