View larger
DS7-34DSX004N0-D 134943 Y7-134943 EATON ELECTRIC Soft starter, 4 A, 200 480 V AC, 24 V DC, Frame size: FS1, ..
DS7-34DSX004N0-D
134943
Y7-134943
EATON - MOELLER
1 Pcs.
Automation > Soft starter
Standard Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller soft starter offers reliable electronic control for standard three-phase electric motors, managing starting currents to prevent premature mechanical wear. These devices are widely utilized in factory automation, HVAC infrastructure, and material transport machinery.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 4 A
- Rated operating voltage Ue (EF002418): 230 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 0.75 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 1.5 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): No
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 40 °C
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Integrated motor overload protection (EF007297): No
- Degree of protection (IP) (EF005474): IP20
- Degree of protection (NEMA) (EF011959): 1
More info
▲General specifications
EN 60947-4-2
CSA Std. C22.2 No. 0-M91
CSA Std. C22.2 No. 14-05
IEC 60947-4-2
C-Tick
CSA22.2-14
CSA-C22.2 No 0-M91
CSA
UkrSEPRO
GB 14048.6
UL
IEC/EN 60947-4-2
CE
CSA-C22.2 No 14-05
Features & Functions
Internal bypass contacts
Single direction
Suppression of DC components for motors
Current limitation, with PKE
Potential isolation between power and control sections
Min. ramp time 1 s - fast switching (semiconductor contactor)
Soft start function
General
NEMA 1
Ambient conditions, mechanical
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Damp heat, constant, to IEC 60068-2-3
Main conducting paths
3 x 170M1359, Type „2“ coordination (additional with the fuses for coordination type „1“), Main conducting paths
Motor rating
Terminal capacities
1 x (0.75 - 2.5) mm², Control circuit cables
1 x (0.75 - 2.5) mm², Main cables
2 x (0.75 - 2.5) mm², Main cables
1 x (0.75 - 4) mm², Main cables
2 x (0.75 - 2.5) mm², Main cables
2 x (0.75 - 2.5) mm², Control circuit cables
18 - 10, Control circuit cables
PZ2, 1 x 6 mm, Terminal screw, Standard screwdriver
1.2 Nm, Screw terminals, Control circuit cables
Control circuit
50 mA, Control circuit, Regulator supply
Input/Output
24 V DC
Soft start function
Max. 100 %, Soft start function, Start voltage = turn-off voltage