DS7-34DSX200N0-D 134959 Y7-134959 EATON ELECTRIC Soft starter, 200 A, 200 480 V AC, 24 V DC, Frame size: FS4..
DS7-34DSX200N0-D
134959
Y7-134959
EATON - MOELLER
1 Pcs.
Automation > Soft starter
Standard Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Reliable motor starting performance in industrial automation panels is achieved through the Eaton Moeller DS7-34DSX200N0-D soft starter. These semiconductor-based controllers limit startup torque and reduce mechanical wear across heavy-duty equipment.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 200 A
- Rated operating voltage Ue (EF002418): 230 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 55 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 110 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): No
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 40 °C
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Integrated motor overload protection (EF007297): No
- Degree of protection (IP) (EF005474): IP20
- Degree of protection (NEMA) (EF011959): 1
More info
▲General specifications
CSA-C22.2 No 0-M91
CSA-C22.2 No 14-05
UL 508
UkrSEPRO
CSA22.2-14
UL
GB 14048.6
CSA
C-Tick
IEC/EN 60947-4-2
Features & Functions
Internal bypass
Current limitation, with PKE
Potential isolation between power and control sections
Suppression of DC components for motors
Single direction
Min. ramp time 1 s - fast switching (semiconductor contactor)
Suppression of closing transients
General
IP20
Ambient conditions, mechanical
Climatic environmental conditions
Max. 2000 m
Damp heat, cyclic, to IEC 60068-2-30
Main conducting paths
3 x 170M5008, Type „2“ coordination (additional with the fuses for coordination type „1“), Main conducting paths
Motor rating
Terminal capacities
2 x 9 x 0.8 mm, Main cables
2 x (0.5 - 0.75) mm², Control circuit cables
1 x (0.5 - 2.5) mm², Control circuit cables
2 x (0.5 - 1.0) mm², Control circuit cables
1 x (4 - 185) mm², Main cables
1 x (21 - 14), Control circuit cables
2 x (12 - 00), Main cables
1 x (12 - 350 kcmil), Main cables
1 x (4 - 185) mm², Main cables
2 x (0.5 - 1.0) mm², Control circuit cables
2 x (4 - 70) mm², Main cables
PZ2, 1 x 6 mm, Terminal screw, Standard screwdriver
14 Nm (> 10 mm²)
5 Nm (≤ 10 mm²)
Control circuit
1.6 mA, Control circuit, Digital inputs, External 24 V
50 mA, Control circuit, Regulator supply
Input/Output
24 V DC (-15 %/+10 %) or via SmartWire-DT
Soft start function
30 s
Max. 100 %, Soft start function, Start voltage = turn-off voltage