View larger
DS7-342SX009N0-N 134928 Y7-134928 EATON ELECTRIC Soft starter, 9 A, 200 480 V AC, Us 110 230 V AC, Frame siz..
DS7-342SX009N0-N
134928
Y7-134928
EATON - MOELLER
1 Pcs.
Automation > Soft starter
Standard Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller soft starter (part number DS7-342SX009N0-N) is a compact solid-state motor controller used to regulate startup currents and protect mechanical drives from excessive torque stress.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 9 A
- Rated operating voltage Ue (EF002418): 230 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 2.2 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 4 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): No
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 40 °C
- Rated control supply voltage AC 50 Hz (EF003978): 110 V
- Rated control supply voltage AC 60 Hz (EF003979): 110 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Integrated motor overload protection (EF007297): No
- Degree of protection (IP) (EF005474): IP20
- Degree of protection (NEMA) (EF011959): 1
More info
▲General specifications
UkrSEPRO
CSA Class No.: 321106
CSA-C22.2 No 14-05
UL 508
UL File No.: E251034
GB 14048.6
CSA File No.: 2511305
CSA-C22.2 No 0-M91
UL
CE
CSA22.2-14
IEC/EN 60947-4-2
CSA
Features & Functions
Internal bypass
Potential isolation between power and control sections
Suppression of DC components for motors
Suppression of closing transients
Single direction
Soft start function
General
NEMA 1
Ambient conditions, mechanical
Climatic environmental conditions
Max. 2000 m
Damp heat, constant, to IEC 60068-2-3
Main conducting paths
3 x 170M1362, Type „2“ coordination (additional with the fuses for coordination type „1“), Main conducting paths
Motor rating
Terminal capacities
1 x (0.75 - 2.5) mm², Main cables
2 x (0.75 - 2.5) mm², Control circuit cables
2 x (0.75 - 2.5) mm², Main cables
2 x (0.75 - 2.5) mm², Control circuit cables
1 x (0.75 - 4) mm², Main cables
2 x (0.75 - 2.5) mm², Main cables
18 - 10, Control circuit cables
0.6 x 5.5 mm/1 x 6 mm, Terminal screws, Control circuit cables
1.2 Nm, Screw terminals, Control circuit cables
Control circuit
50 mA, Control circuit, Regulator supply
Input/Output
110 - 230 V AC
Soft start function
Max. 100 %, Soft start function, Start voltage = turn-off voltage