S811+V85V3S 169010 Y7-169010 EATON ELECTRIC Soft starter, 850 A, 200 690 V AC, Us 24 V DC, with control unit..
S811+V85V3S
169010
Y7-169010
EATON - MOELLER
1 Pcs.
Automation > Soft starter
High Performance Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Operated as an Eaton Moeller S811+V85V3S soft starter, this heavy-duty component controls heavy electrical loads by gradually ramping up voltage to industrial motors. Industrial installations deploy these units to protect mechanical drives and reduce peak electrical currents during startup.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 850 A
- Rated operating voltage Ue (EF002418): 200 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 200 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 450 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): Yes
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 50 °C
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Integrated motor overload protection (EF007297): Yes
- Release class (EF006668): Adjustable
- Degree of protection (IP) (EF005474): IP00
More info
▲General specifications
UL 508
C-Tick
CCC
UL File No.: E202571
IEC/EN 60947-4-2
CE
CSA22.2-14-1995
UL
UL Category Control No.: NMFT
GB14048
Features & Functions
Motor overload protection
Internal bypass contacts
Display
Suppression of DC components for motors
Current limitation
Single direction
Potential isolation between power and control sections
Overload monitoring
Soft start function
Suppression of closing transients
Underload monitoring
General
NEMA Other
CLASS 30 (6 x Iₑ for 30 s)
CLASS 10 (star-delta replacement)
Climatic environmental conditions
Above 2000 m with 0.5 % derating per 100 m
Damp heat, constant, to IEC 60068-2-3
Main conducting paths
Motor rating
Terminal capacities
4 x (70 - 240) mm², Main cables
1 x (2.5 - 4) mm², Control circuit cables
2 x (1 - 2.5) mm², Control circuit cables
6 x (120 - 240) mm², Main cables
6 x (120 - 240) mm², Main cables
1 x (2.5 - 4) mm², Control circuit cables
2 x (1 - 2.5) mm², Control circuit cables
2 x (120 - 240) mm², Main cables
4 x (4 - 500 kcmil), Main cables
2 x (14 - 12), Control circuit cables
6 x (4 - 500 kcmil), Main cables
1 x (14 - 12), Control circuit cables
2 x (1 - 2.5) mm², Control circuit cables
2 x (120 - 240) mm², Main cables
6 x (120 - 240) mm², Main cables
4 x (70 - 240) mm², Main cables
Control circuit
150 mA, Control circuit, Digital inputs, External 24 V
10 A/150 ms, Control circuit, Regulator supply at peak performance (close bypass) at 24 V DC
100 mA, Control circuit, Digital inputs, External 24 V (no-load)
Input/Output
24 V DC
Soft start function
Max. 2000 ms (Kickstart Duration)