S811+V72V3S 169007 Y7-169007 EATON ELECTRIC Soft starter, 720 A, 200 690 V AC, Us 24 V DC, with control unit..
S811+V72V3S
169007
Y7-169007
EATON - MOELLER
1 Pcs.
Automation > Soft starter
High Performance Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Electric soft starter S811+V72V3S regulates high-power industrial motor acceleration to prevent electrical grid strain and mechanical stress. Heavy-duty manufacturing facilities rely on these units for reliable control over large machinery.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 720 A
- Rated operating voltage Ue (EF002418): 200 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 200 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 400 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): Yes
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 50 °C
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Integrated motor overload protection (EF007297): Yes
- Release class (EF006668): Adjustable
- Degree of protection (IP) (EF005474): IP20
More info
▲General specifications
GB14048
CCC
CSA22.2-14-1995
UL
UL 508
UL File No.: E202571
CE
CSA
IEC/EN 60947-4-2
UL Category Control No.: NMFT
Features & Functions
Internal bypass contacts
Motor overload protection
Display
Soft start function
Potential isolation between power and control sections
Current limitation
Underload monitoring
Min. ramp time 1 s - fast switching (semiconductor contactor)
Overload monitoring
Suppression of DC components for motors
Suppression of closing transients
General
NEMA Other
CLASS 20 (heavy starting duty 3 x Iₑ for 45 s)
CLASS 10 (star-delta replacement)
Climatic environmental conditions
Above 2000 m with 0.5 % derating per 100 m
Damp heat, constant, to IEC 60068-2-3
Main conducting paths
Motor rating
Terminal capacities
4 x (70 - 240) mm², Main cables
6 x (120 - 240) mm², Main cables
1 x (2.5 - 4) mm², Control circuit cables
2 x (120 - 240) mm², Main cables
4 x (70 - 240) mm², Main cables
2 x (120 - 240) mm², Main cables
1 x (2.5 - 4) mm², Control circuit cables
6 x (120 - 240) mm², Main cables
4 x (4 - 500 kcmil), Main cables
2 x (14 - 12), Control circuit cables
1 x (14 - 12), Control circuit cables
2 x (4 - 500 kcmil), Main cables
4 x (70 - 240) mm², Main cables
1 x (2.5 - 4) mm², Control circuit cables
2 x (1 - 2.5) mm², Control circuit cables
2 x (120 - 240) mm², Main cables
Control circuit
1400 mA, Control circuit, Regulator supply
10 A/150 ms, Control circuit, Regulator supply at peak performance (close bypass) at 24 V DC
100 mA, Control circuit, Digital inputs, External 24 V (no-load)
Input/Output
24 V DC (-10 %/+10 %)
Soft start function
Max. 2000 ms (Kickstart Duration)