View larger
DS7-342SX070N0-N 134936 Y7-134936 EATON ELECTRIC Soft starter, 70 A, 200 480 V AC, Us 110 230 V AC, Frame si..
DS7-342SX070N0-N
134936
Y7-134936
EATON - MOELLER
1 Pcs.
Automation > Soft starter
Standard Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller DS7-342SX070N0-N soft starter smoothly accelerates industrial motors by ramping up the voltage, reducing mechanical stress on belts and gearboxes. Panel builders incorporate these compact units to optimize electrical safety and performance in motor control circuits. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 70 A
- Rated operating voltage Ue (EF002418): 230 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 15 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 37 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): No
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 40 °C
- Rated control supply voltage AC 50 Hz (EF003978): 110 V
- Rated control supply voltage AC 60 Hz (EF003979): 110 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Integrated motor overload protection (EF007297): No
- Degree of protection (IP) (EF005474): IP20
- Degree of protection (NEMA) (EF011959): 1
More info
▲General specifications
CSA Class No.: 321106
GB 14048.6
CSA-C22.2 No 0-M91
CSA
IEC/EN 60947-4-2
C-Tick
UL File No.: E251034
UL
CE
UL 508
UkrSEPRO
CSA File No.: 2511305
CSA-C22.2 No 14-05
Features & Functions
Internal bypass contacts
Suppression of DC components for motors
Soft start function
Min. ramp time 1 s - fast switching (semiconductor contactor)
Potential isolation between power and control sections
Single direction
General
IP20
Ambient conditions, mechanical
Climatic environmental conditions
Max. 2000 m
Damp heat, constant, to IEC 60068-2-3
Main conducting paths
NZMN1-M80, Type “1” coordination, Main conducting paths
Motor rating
Terminal capacities
9 x 9 x 0.8 mm, Main cables
2 x (0.5 - 0.75) mm², Control circuit cables
1 x (0.5 - 2.5) mm², Control circuit cables
2 x (0.5 - 1.0) mm², Control circuit cables
1 x (25 - 70) mm², Main cables
1 x (12 - 2/0), Main cables
1 x (21 - 14), Control circuit cables
2 x (0.5 - 1.0) mm², Control circuit cables
2 x (6 - 25) mm², Main cables
1 x (0.5 - 1.5) mm², Control circuit cables
0.6 x 3.5 mm, Terminal screws, Control circuit cables
9 Nm (> 10 mm²)
6 Nm (≤ 10 mm²)
Control circuit
1.6 mA, Control circuit, Digital inputs, External 24 V
0,6 A/50 ms, Control circuit, Regulator supply at peak performance (close bypass) at 24 V DC
Input/Output
110 - 230 V AC
Soft start function
Min. 30 %, Soft start function, Start voltage = turn-off voltage