S811+N66P3S 168979 Y7-168979 EATON ELECTRIC Soft starter, 66 A, 200 600 V AC, Us 24 V DC, with control unit ..
S811+N66P3S
168979
Y7-168979
EATON - MOELLER
1 Pcs.
Automation > Soft starter
High Performance Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The S811+N66P3S Eaton Moeller soft starter provides reliable solid-state motor control by managing voltage application during startup and shutdown routines. Heavy-duty manufacturing installations use these controllers to safeguard mechanical equipment and reduce electrical grid loads.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 66 A
- Rated operating voltage Ue (EF002418): 200 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 18.5 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 30 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): Yes
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 50 °C
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Integrated motor overload protection (EF007297): Yes
- Release class (EF006668): Adjustable
- Degree of protection (IP) (EF005474): IP20
More info
▲General specifications
CE
CSA Class No.: 3211-06, 2411-01
CSA22.2-14-1995
UL File No.: E202571
CSA
CSA File No.: LR 353
UL
IEC/EN 60947-4-2
UL Category Control No.: NMFT
GB14048
CSA-C22.2 No. 14
UL 508
C-Tick
Features & Functions
Internal bypass
Motor overload protection
Display
Overload monitoring
Underload monitoring
Single direction
Soft start function
Potential isolation between power and control sections
Current limitation
Suppression of closing transients
Min. ramp time 1 s - fast switching (semiconductor contactor)
General
NEMA Other
CLASS 10 (star-delta replacement)
CLASS 20 (heavy starting duty 3 x Iₑ for 45 s)
Climatic environmental conditions
Max. 2000 m
Damp heat, cyclic, to IEC 60068-2-30
Main conducting paths
Motor rating
Terminal capacities
1 x (2.5 - 4) mm², Control circuit cables
2 x (1 - 2.5) mm², Control circuit cables
1 x (2.5 - 4) mm², Control circuit cables
1 x (2.5 - 35) mm², Main cables
1 x (14 - 2), Main cables
2 x (14 - 12), Control circuit cables
1 x (2.5 - 4) mm², Control circuit cables
2 x (1 - 2.5) mm², Control circuit cables
1.5 x 6 mm, Terminal screw, Main cables
4 Nm (≤ 6 mm²)
4.5 Nm (≤ 10 mm²)
0.4 Nm, Screw terminals, Control circuit cables
5 Nm (≤ 25 mm²)
Control circuit
10 A/150 ms, Control circuit, Regulator supply at peak performance (close bypass) at 24 V DC
100 mA, Control circuit, Digital inputs, External 24 V (no-load)
150 mA, Control circuit, Digital inputs, External 24 V
Input/Output
24 V DC (-10 %/+10 %)
Soft start function
100% (Kickstart voltage)