S811+V65P3S 169003 Y7-169003 EATON ELECTRIC Soft starter, 650 A, 200 600 V AC, Us 24 V DC, with control unit..
S811+V65P3S
169003
Y7-169003
EATON - MOELLER
1 Pcs.
Automation > Soft starter
High Performance Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
High-capacity motor systems require robust components such as the S811+V65P3S Eaton Moeller soft starter to handle massive electrical loads during startup sequences. Large industrial infrastructure employs these high-amp units to protect major pumps, compressors, and industrial milling equipment. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 650 A
- Rated operating voltage Ue (EF002418): 200 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 200 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 315 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): Yes
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 50 °C
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Integrated motor overload protection (EF007297): Yes
- Release class (EF006668): Adjustable
- Degree of protection (IP) (EF005474): IP00
More info
▲General specifications
IEC 60947-4-2
UL Recognized
EN 60947-4-2
UL Listed
CSA Certified for Elevator Duty
UL 508
CE
CSA-C22.2 No. 14
UL
CSA
C-Tick
CSA Class No.: 3211-06
CCC
IEC/EN 60947-4-2
CSA22.2-14-1995
GB14048
UL Category Control No.: NMFT
UL File No.: E202571
CSA File No.: LR 353
Features & Functions
Display
Internal bypass contacts
Motor overload protection
Underload monitoring
Current limitation
Suppression of closing transients
Single direction
Suppression of DC components for motors
Overload monitoring
Potential isolation between power and control sections
Soft start function
General
NEMA Other
CLASS 10 (star-delta replacement)
CLASS 30 (6 x Iₑ for 30 s)
Climatic environmental conditions
Max. 2000 m
Damp heat, cyclic, to IEC 60068-2-30
Main conducting paths
Motor rating
Terminal capacities
2 x (1 - 2.5) mm², Control circuit cables
2 x (120 - 240) mm², Main cables
4 x (70 - 240) mm², Main cables
6 x (120 - 240) mm², Main cables
2 x (120 - 240) mm², Main cables
1 x (2.5 - 4) mm², Control circuit cables
6 x (120 - 240) mm², Main cables
2 x (1 - 2.5) mm², Control circuit cables
6 x (4 - 500 kcmil), Main cables
2 x (14 - 12), Control circuit cables
1 x (14 - 12), Control circuit cables
2 x (4 - 500 kcmil), Main cables
2 x (1 - 2.5) mm², Control circuit cables
2 x (120 - 240) mm², Main cables
4 x (70 - 240) mm², Main cables
6 x (120 - 240) mm², Main cables
Control circuit
1400 mA, Control circuit, Regulator supply
150 mA, Control circuit, Digital inputs, External 24 V
100 mA, Control circuit, Digital inputs, External 24 V (no-load)
Input/Output
24 V DC (-10 %/+10 %)
Soft start function
Max. 2000 ms (Kickstart Duration)