View larger
S811+V65N3S 169002 S811PLUSV65N3S EATON ELECTRIC Soft starter, 650 A, 200 600 V AC, Us 24 V DC, with control..
S811+V65N3S
169002
S811PLUSV65N3S
EATON - MOELLER
1 Pcs.
Automation > Soft starter
High Performance Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller S811+V65N3S is an advanced heavy-duty soft starter built to provide controlled acceleration and deceleration for high-power electric motors. Industrial facilities rely on these units to minimize voltage dips and mechanical stress across large manufacturing infrastructure.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 650 A
- Rated operating voltage Ue (EF002418): 200 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 200 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 315 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): Yes
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 50 °C
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Integrated motor overload protection (EF007297): Yes
- Release class (EF006668): Adjustable
- Degree of protection (IP) (EF005474): IP00
More info
▲General specifications
UL Listed
EN 60947-4-2
UL Recognized
CSA file No. 3211-06
CSA Certified for Elevator Duty
IEC/EN 60947-4-2
CSA File No.: LR 353
UL File No.: E202571
UL
CSA Class No.: 3211-06
CCC
CSA22.2-14-1995
GB14048
UL 508
UL Category Control No.: NMFT
CE
CSA-C22.2 No. 14
C-Tick
CSA
Features & Functions
Display
Internal bypass
Motor overload protection
Suppression of closing transients
Potential isolation between power and control sections
Current limitation
Suppression of DC components for motors
Single direction
Underload monitoring
Min. ramp time 1 s - fast switching (semiconductor contactor)
Overload monitoring
General
NEMA Other
CLASS 30 (6 x Iₑ for 30 s)
CLASS 20 (heavy starting duty 3 x Iₑ for 45 s)
Climatic environmental conditions
Max. 2000 m
Damp heat, constant, to IEC 60068-2-3
Main conducting paths
Motor rating
Terminal capacities
1 x (2.5 - 4) mm², Control circuit cables
2 x (1 - 2.5) mm², Control circuit cables
6 x (120 - 240) mm², Main cables
2 x (120 - 240) mm², Main cables
4 x (70 - 240) mm², Main cables
2 x (1 - 2.5) mm², Control circuit cables
2 x (120 - 240) mm², Main cables
6 x (120 - 240) mm², Main cables
6 x (4 - 500 kcmil), Main cables
1 x (14 - 12), Control circuit cables
4 x (4 - 500 kcmil), Main cables
2 x (4 - 500 kcmil), Main cables
2 x (1 - 2.5) mm², Control circuit cables
2 x (120 - 240) mm², Main cables
4 x (70 - 240) mm², Main cables
6 x (120 - 240) mm², Main cables
Control circuit
10 A/150 ms, Control circuit, Regulator supply at peak performance (close bypass) at 24 V DC
100 mA, Control circuit, Digital inputs, External 24 V (no-load)
150 mA, Control circuit, Digital inputs, External 24 V
Input/Output
24 V DC
Soft start function
100% (Kickstart voltage)