View larger
S811+V50V3S 169001 Y7-169001 EATON ELECTRIC Soft starter, 500 A, 200 690 V AC, Us 24 V DC, with control unit..
S811+V50V3S
169001
Y7-169001
EATON - MOELLER
1 Pcs.
Automation > Soft starter
High Performance Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Electric soft starter regulates the voltage supplied to heavy industrial motors, ensuring smooth starts and stops that preserve gearboxes, couplings, and belts from premature failure. Large-scale processing plants and pumping stations rely on these heavy-duty controllers to manage high-horsepower loads efficiently.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 500 A
- Rated operating voltage Ue (EF002418): 200 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 160 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 250 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): Yes
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 50 °C
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Integrated motor overload protection (EF007297): Yes
- Release class (EF006668): Adjustable
- Degree of protection (IP) (EF005474): IP00
More info
▲General specifications
CSA22.2-14-1995
C-Tick
UL
CCC
GB14048
UL 508
IEC/EN 60947-4-2
CSA
CE
UL Category Control No.: NMFT
Features & Functions
Internal bypass
Display
Internal bypass contacts
Soft start function
Potential isolation between power and control sections
Overload monitoring
Single direction
Suppression of DC components for motors
Suppression of closing transients
Current limitation
Underload monitoring
General
NEMA Other
CLASS 20 (heavy starting duty 3 x Iₑ for 45 s)
CLASS 30 (6 x Iₑ for 30 s)
Climatic environmental conditions
Above 2000 m with 0.5 % derating per 100 m
Damp heat, constant, to IEC 60068-2-3
Main conducting paths
Motor rating
Terminal capacities
1 x (2.5 - 4) mm², Control circuit cables
2 x (1 - 2.5) mm², Control circuit cables
4 x (70 - 240) mm², Main cables
6 x (120 - 240) mm², Main cables
2 x (1 - 2.5) mm², Control circuit cables
2 x (120 - 240) mm², Main cables
6 x (120 - 240) mm², Main cables
4 x (70 - 240) mm², Main cables
6 x (4 - 500 kcmil), Main cables
1 x (14 - 12), Control circuit cables
2 x (4 - 500 kcmil), Main cables
2 x (14 - 12), Control circuit cables
6 x (120 - 240) mm², Main cables
4 x (70 - 240) mm², Main cables
2 x (1 - 2.5) mm², Control circuit cables
2 x (120 - 240) mm², Main cables
Control circuit
150 mA, Control circuit, Digital inputs, External 24 V
100 mA, Control circuit, Digital inputs, External 24 V (no-load)
1400 mA, Control circuit, Regulator supply
Input/Output
24 V DC (-10 %/+10 %)
Soft start function
100% (Kickstart voltage)