View larger
S811+V50N3S 168999 S811PLUSV50N3S EATON ELECTRIC Soft starter, 500 A, 200 600 V AC, Us 24 V DC, with control..
S811+V50N3S
168999
S811PLUSV50N3S
EATON - MOELLER
1 Pcs.
Automation > Soft starter
High Performance Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller S811+V50N3S operates as a high-performance soft starter designed to regulate high-current motor setups in industrial plants. Utilization of this hardware prevents harmful mechanical jarring during startup, safeguarding linked gears and drive shafts from premature failure.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 500 A
- Rated operating voltage Ue (EF002418): 200 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 160 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 250 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): Yes
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 50 °C
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Integrated motor overload protection (EF007297): Yes
- Release class (EF006668): Adjustable
- Degree of protection (IP) (EF005474): IP20
More info
▲General specifications
CSA
CSA File No.: LR 353
CSA Class No.: 3211-06
CSA22.2-14-1995
IEC/EN 60947-4-2
CSA-C22.2 No. 14
UL
UL File No.: E202571
CE
GB14048
CCC
UL Category Control No.: NMFT
UL 508
Features & Functions
Motor overload protection
Internal bypass
Internal bypass contacts
Underload monitoring
Soft start function
Suppression of DC components for motors
Current limitation
Min. ramp time 1 s - fast switching (semiconductor contactor)
Potential isolation between power and control sections
Single direction
Suppression of closing transients
General
NEMA Other
CLASS 10 (star-delta replacement)
CLASS 20 (heavy starting duty 3 x Iₑ for 45 s)
Climatic environmental conditions
Max. 2000 m
Damp heat, constant, to IEC 60068-2-3
Main conducting paths
Motor rating
Terminal capacities
6 x (120 - 240) mm², Main cables
2 x (1 - 2.5) mm², Control circuit cables
1 x (2.5 - 4) mm², Control circuit cables
4 x (70 - 240) mm², Main cables
2 x (120 - 240) mm², Main cables
4 x (70 - 240) mm², Main cables
2 x (1 - 2.5) mm², Control circuit cables
1 x (2.5 - 4) mm², Control circuit cables
4 x (4 - 500 kcmil), Main cables
1 x (14 - 12), Control circuit cables
2 x (14 - 12), Control circuit cables
6 x (4 - 500 kcmil), Main cables
4 x (70 - 240) mm², Main cables
6 x (120 - 240) mm², Main cables
2 x (1 - 2.5) mm², Control circuit cables
1 x (2.5 - 4) mm², Control circuit cables
Control circuit
10 A/150 ms, Control circuit, Regulator supply at peak performance (close bypass) at 24 V DC
100 mA, Control circuit, Digital inputs, External 24 V (no-load)
1400 mA, Control circuit, Regulator supply
Input/Output
24 V DC (-10 %/+10 %)
Soft start function
100% (Kickstart voltage)