View larger
S811+N37N3S 168976 S811PLUSN37N3S EATON ELECTRIC Soft starter, 3p, 37A, Ue 200-600VAC
S811+N37N3S
168976
S811PLUSN37N3S
EATON - MOELLER
1 Pcs.
Automation > Soft starter
High Performance Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Precise voltage ramping and inrush current limitation are provided by the S811+N37N3S Eaton Moeller soft starter, ensuring smooth motor startup. These compact electronic units protect mechanical transmissions and electrical distribution networks in diverse industrial manufacturing applications.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 37 A
- Rated operating voltage Ue (EF002418): 200 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 7.5 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 18.5 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): Yes
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 50 °C
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Integrated motor overload protection (EF007297): Yes
- Release class (EF006668): Adjustable
- Degree of protection (IP) (EF005474): IP20
More info
▲General specifications
CSA22.2-14-1995
UL 508
CSA Class No.: 3211-06, 2411-01
UL Category Control No.: NMFT
C-Tick
CE
CSA-C22.2 No. 14
CSA File No.: LR 353
IEC/EN 60947-4-2
UL
CCC
GB14048
UL File No.: E202571
Features & Functions
Internal bypass contacts
Motor overload protection
Internal bypass
Soft start function
Suppression of closing transients
Suppression of DC components for motors
Overload monitoring
Min. ramp time 1 s - fast switching (semiconductor contactor)
Current limitation
Underload monitoring
Single direction
General
NEMA Other
CLASS 30 (6 x Iₑ for 30 s)
CLASS 10 (star-delta replacement)
Climatic environmental conditions
Above 2000 m with 0.5 % derating per 100 m
Damp heat, cyclic, to IEC 60068-2-30
Main conducting paths
Motor rating
Terminal capacities
2 x (1 - 2.5) mm², Control circuit cables
1 x (2.5 - 35) mm², Main cables
1 x (2.5 - 35) mm², Main cables
2 x (1 - 2.5) mm², Control circuit cables
1 x (14 - 12), Control circuit cables
2 x (14 - 12), Control circuit cables
2 x (1 - 2.5) mm², Control circuit cables
1 x (2.5 - 4) mm², Control circuit cables
1.5 x 6 mm, Terminal screw, Main cables
0.4 Nm, Screw terminals, Control circuit cables
4.5 Nm (≤ 10 mm²)
5.6 Nm (> 25 mm²)
5 Nm (≤ 25 mm²)
Control circuit
150 mA, Control circuit, Digital inputs, External 24 V
100 mA, Control circuit, Digital inputs, External 24 V (no-load)
10 A/150 ms, Control circuit, Regulator supply at peak performance (close bypass) at 24 V DC
Input/Output
24 V DC
Soft start function
100% (Kickstart voltage)