View larger
DS7-342SX032N0-N 134932 Y7-134932 EATON ELECTRIC Soft starter, 3p, 32A, 200-480VAC, us 110/230VAC
DS7-342SX032N0-N
134932
Y7-134932
EATON - MOELLER
1 Pcs.
Automation > Soft starter
Standard Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This Eaton Moeller DS7-342SX032N0-N soft starter manages three-phase motor startup profiles to mitigate mechanical stress across dynamic industrial applications. Industrial automation panels use such devices to regulate starting current and extend the operational life of connected machinery. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 32 A
- Rated operating voltage Ue (EF002418): 230 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 7.5 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 15 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): No
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 40 °C
- Rated control supply voltage AC 50 Hz (EF003978): 110 V
- Rated control supply voltage AC 60 Hz (EF003979): 110 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Integrated motor overload protection (EF007297): No
- Degree of protection (IP) (EF005474): IP20
- Degree of protection (NEMA) (EF011959): 1
More info
▲General specifications
UL File No.: E251034
CSA File No.: 2511305
GB 14048.6
IEC/EN 60947-4-2
CSA Class No.: 321106
CSA
CE
UkrSEPRO
CSA-C22.2 No 14-05
UL
C-Tick
CSA22.2-14
CSA-C22.2 No 0-M91
Features & Functions
Internal bypass contacts
Suppression of closing transients
Potential isolation between power and control sections
Min. ramp time 1 s - fast switching (semiconductor contactor)
Suppression of DC components for motors
Soft start function
General
NEMA 1
Ambient conditions, mechanical
Climatic environmental conditions
Max. 2000 m
Damp heat, cyclic, to IEC 60068-2-30
Main conducting paths
PKM0-32 (+ CL-PKZ0), Type “1” coordination, Main conducting paths
Motor rating
Terminal capacities
2 x (0.75 - 10) mm², Main cables
1 x (0.75 - 16) mm², Main cables
2 x (0.5 - 0.75) mm², Control circuit cables
2 x (0.75 - 10) mm², Main cables
1 x (0.5 - 2.5) mm², Control circuit cables
1 x (0.75 - 16) mm², Main cables
18 - 6, Main cables
2 x (21 - 18), Control circuit cables
2 x (0.5 - 1.0) mm², Control circuit cables
1 x 16 mm², Main cables
0.6 x 5.5 mm/1 x 6 mm, Terminal screws, Control circuit cables
1.2 Nm, Screw terminals, Control circuit cables
Control circuit
50 mA, Control circuit, Regulator supply
Input/Output
110 - 230 V AC (-15 %/+10 %)
Soft start function
Max. 100 %, Soft start function, Start voltage = turn-off voltage