S811+T30P3S 168991 Y7-168991 EATON ELECTRIC Soft starter, 3p, 304A, Ue 200-600VAC
S811+T30P3S
168991
Y7-168991
EATON - MOELLER
1 Pcs.
Automation > Soft starter
High Performance Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller S811+T30P3S soft starter regulates voltage application to large electric motors, ensuring smooth starting and stopping sequences. Facilities utilize these units to mitigate mechanical shocks and extend the lifecycle of high-power industrial equipment.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 304 A
- Rated operating voltage Ue (EF002418): 200 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 90 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 160 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): Yes
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 50 °C
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Integrated motor overload protection (EF007297): Yes
- Release class (EF006668): Adjustable
- Degree of protection (IP) (EF005474): IP20
More info
▲General specifications
UL 508
CSA
GB14048
UL File No.: E202571
UL
IEC/EN 60947-4-2
C-Tick
CCC
CE
CSA Class No.: 3211-06, 2411-01
CSA22.2-14-1995
CSA File No.: LR 353
CSA-C22.2 No. 14
Features & Functions
Internal bypass
Internal bypass contacts
Display
Suppression of closing transients
Single direction
Overload monitoring
Potential isolation between power and control sections
Soft start function
Suppression of DC components for motors
Underload monitoring
Min. ramp time 1 s - fast switching (semiconductor contactor)
General
NEMA Other
CLASS 20 (heavy starting duty 3 x Iₑ for 45 s)
CLASS 30 (6 x Iₑ for 30 s)
Climatic environmental conditions
Above 2000 m with 0.5 % derating per 100 m
Damp heat, constant, to IEC 60068-2-3
Main conducting paths
Motor rating
Terminal capacities
1 x (70 - 240) mm², Main cables
1 x (2.5 - 4) mm², Control circuit cables
2 x (1 - 2.5) mm², Control circuit cables
1 x (2.5 - 4) mm², Control circuit cables
2 x (1 - 2.5) mm², Control circuit cables
2 x (25 - 240) mm², Main cables
2 x (4 - 500 kcmil), Main cables
1 x (14 - 12), Control circuit cables
2 x (14 - 12), Control circuit cables
2 x (25 - 240) mm², Main cables
1 x (70 - 240) mm², Main cables
1 x (2.5 - 4) mm², Control circuit cables
0.6 x 3.5 mm, Terminal screws, Control circuit cables
0.4 Nm, Screw terminals, Control circuit cables
28.3 Nm (> 150 mm²)
Control circuit
1000 mA, Control circuit, Regulator supply
100 mA, Control circuit, Digital inputs, External 24 V (no-load)
10 A/150 ms, Control circuit, Regulator supply at peak performance (close bypass) at 24 V DC
Input/Output
24 V DC
Soft start function
100% (Kickstart voltage)