View larger
S811+T24P3S 168988 Y7-168988 EATON ELECTRIC Soft starter, 3p, 240A, Ue 200-600VAC
S811+T24P3S
168988
Y7-168988
EATON - MOELLER
1 Pcs.
Automation > Soft starter
High Performance Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Electric soft starter delivers robust electronic control for high-power industrial motors, ensuring gradual acceleration and deceleration to prevent mechanical stress. Heavy manufacturing plants incorporate these high-capacity units into their primary drive systems for enhanced operational safety.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 240 A
- Rated operating voltage Ue (EF002418): 200 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 75 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 132 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): Yes
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 50 °C
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Integrated motor overload protection (EF007297): Yes
- Release class (EF006668): Adjustable
- Degree of protection (IP) (EF005474): IP00
More info
▲General specifications
UL Recognized
UL Listed
IEC 60947-4-2
CSA file No. 3211-06
CSA Certified for Elevator Duty
IEC/EN 60947-4-2
GB14048
CE
UL 508
UL Category Control No.: NMFT
CSA
UL File No.: E202571
CSA File No.: LR 353
CCC
CSA Class No.: 3211-06, 2411-01
CSA-C22.2 No. 14
UL
C-Tick
CSA22.2-14-1995
Features & Functions
Motor overload protection
Display
Internal bypass
Underload monitoring
Current limitation
Suppression of DC components for motors
Min. ramp time 1 s - fast switching (semiconductor contactor)
Soft start function
Overload monitoring
Single direction
Suppression of closing transients
General
NEMA Other
CLASS 20 (heavy starting duty 3 x Iₑ for 45 s)
CLASS 30 (6 x Iₑ for 30 s)
Climatic environmental conditions
Above 2000 m with 0.5 % derating per 100 m
Damp heat, cyclic, to IEC 60068-2-30
Main conducting paths
Motor rating
Terminal capacities
2 x (25 - 240) mm², Main cables
2 x (1 - 2.5) mm², Control circuit cables
1 x (70 - 240) mm², Main cables
2 x (25 - 240) mm², Main cables
2 x (1 - 2.5) mm², Control circuit cables
1 x (70 - 240) mm², Main cables
2 x (4 - 500 kcmil), Main cables
1 x (4 - 500 kcmil), Main cables
1 x (14 - 12), Control circuit cables
1 x (70 - 240) mm², Main cables
2 x (25 - 240) mm², Main cables
1 x (2.5 - 4) mm², Control circuit cables
4 mm Hexagon socket-head screw, Terminal screw, Main cables
28.3 Nm (> 150 mm²)
0.4 Nm, Screw terminals, Control circuit cables
Control circuit
100 mA, Control circuit, Digital inputs, External 24 V (no-load)
1000 mA, Control circuit, Regulator supply
150 mA, Control circuit, Digital inputs, External 24 V
Input/Output
24 V DC
Soft start function
100% (Kickstart voltage)