S811+T18P3S 168985 Y7-168985 EATON ELECTRIC Soft starter, 3p, 180A, Ue 200-600VAC
S811+T18P3S
168985
Y7-168985
EATON - MOELLER
1 Pcs.
Automation > Soft starter
High Performance Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A soft starter facilitates smooth motor acceleration by regulating voltage input, protecting mechanical shafts and electrical networks from heavy startup shock. Industrial applications use these devices to extend the service life of pumps, fans, and conveyors. The Eaton Moeller S811+T18P3S unit provides reliable solid-state control for three-phase systems. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 180 A
- Rated operating voltage Ue (EF002418): 200 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 55 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 90 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): Yes
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 50 °C
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Integrated motor overload protection (EF007297): Yes
- Release class (EF006668): Adjustable
- Degree of protection (IP) (EF005474): IP20
More info
▲General specifications
UL Recognized
UL Listed
IEC 60947-4-2
CSA file No. 3211-06
CSA Certified for Elevator Duty
C-Tick
UL Category Control No.: NMFT
CSA
CSA22.2-14-1995
CCC
CSA Class No.: 3211-06, 2411-01
CE
UL File No.: E202571
CSA-C22.2 No. 14
GB14048
UL
IEC/EN 60947-4-2
UL 508
CSA File No.: LR 353
Features & Functions
Internal bypass contacts
Motor overload protection
Internal bypass
Min. ramp time 1 s - fast switching (semiconductor contactor)
Soft start function
Suppression of DC components for motors
Current limitation
Potential isolation between power and control sections
Suppression of closing transients
Underload monitoring
Single direction
General
NEMA Other
CLASS 30 (6 x Iₑ for 30 s)
CLASS 20 (heavy starting duty 3 x Iₑ for 45 s)
Climatic environmental conditions
Max. 2000 m
Damp heat, constant, to IEC 60068-2-3
Main conducting paths
Motor rating
Terminal capacities
2 x (25 - 240) mm², Main cables
2 x (1 - 2.5) mm², Control circuit cables
1 x (70 - 240) mm², Main cables
1 x (2.5 - 4) mm², Control circuit cables
2 x (1 - 2.5) mm², Control circuit cables
1 x (70 - 240) mm², Main cables
2 x (14 - 12), Control circuit cables
1 x (4 - 500 kcmil), Main cables
2 x (4 - 500 kcmil), Main cables
2 x (25 - 240) mm², Main cables
1 x (2.5 - 4) mm², Control circuit cables
1 x (70 - 240) mm², Main cables
4 mm Hexagon socket-head screw, Terminal screw, Main cables
0.4 Nm, Screw terminals, Control circuit cables
28.3 Nm (> 150 mm²)
Control circuit
10 A/150 ms, Control circuit, Regulator supply at peak performance (close bypass) at 24 V DC
100 mA, Control circuit, Digital inputs, External 24 V (no-load)
150 mA, Control circuit, Digital inputs, External 24 V
Input/Output
24 V DC (-10 %/+10 %)
Soft start function
Max. 2000 ms (Kickstart Duration)